The effects of 21 and 23 milimeter aortic valve prosthesis on hemodynamic performance and functional capacity in young adults

نویسندگان

  • Ali Umit Yener
  • Sedat Ozcan
  • Ali Baran Budak
  • Serhat Bahadir Genc
  • Turgut Ozkan
  • Omer Faruk Cicek
چکیده

OBJECTIVE Early and medium-term improvement of functional capacity and regression of left ventricular hypertrophy was evaluated in the young adult patient group following application of 21 mm or 23 mm bileaflet aortic mechanical valve prosthesis due to aortic stenosis. Methods : Twenty two patients (10 male, 12 female; mean age 27+-8.2 (19-43)) who underwent isolated aortic valve replacement due to rheumatic aortic stenosis, were included in the study. 21 mm and 23 mm bileaflet mechanical prosthesis was used respectively in eight and fourteen patients. The mean body surface area was 1.86 m(2) and 1.68 m(2) respectively in 23 mm and 21 mm prosthesis while 1.73 ±0.25 m(2) for the whole group. Functional capacity was New York Heart Association (NYHA) class II in 9 patients and class III in thirteen patients. Implantation was performed without enlarging the aortic root in all except four patients. In all patients transvalvular gradients, effective orifice area and the diameter of left ventricle were measured with transthoracic echocardiography during rest and after maximal exercise. Mean follow-up was 34±12 months (range 11-57 months). RESULTS There were no postoperative complications or deaths. All the patients were assessed as NYHA class I with regards to functional capacity (p=0.01). Significant improvements were determined in postoperative mean transvalvular gradient (p=0.005) and left ventricular mass index (p=0.01) when compared with preoperative values. CONCLUSION Our findings show that replacement with 21 mm and 23 mm mechanical prosthesis provides a significant improvement in regression of symptoms and increase of functional capacity in young adults in early and mid-period without increasing mortality and morbidity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis

Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...

متن کامل

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

Hemodynamic comparison of bioprostheses for complete supra-annular position in patients with small aortic annulus.

OBJECTIVES The present study evaluates complete supra-annular bioprostheses in patients with an aortic annulus of 18 to 23 mm in diameter. BACKGROUND Aortic valve replacement in patients with small aortic annulus using stented bioprostheses is often associated with unsatisfactory hemodynamic results and high incidence of patient-prosthesis mismatch. METHODS Between February 2000 and January...

متن کامل

Medium-term results after implant of a new generation stentless aortic prosthesis: hemodynamic performance of medtronic 3F® stentless equine pericardial aortic valve

Methods Between March 2007 and December 2012 a total of 120 consecutive patients affected by aortic valve disease received a 3F valve at our unit. The size ranged between 21 and 29, with prevalence of 23 and 25 implants .Mean age at operation was 75,6 ± 8,0 years, 54% were males, the mean logistic EuroScore was 8,7 ± 5,2 and 47% received concomitant procedures. For isolated replacements the mea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 30  شماره 

صفحات  -

تاریخ انتشار 2014