Characteristics and outcomes of diabetic patients with an implantable cardioverter defibrillator in a real world setting: results from the Israeli ICD registry
نویسندگان
چکیده
AIMS There are limited data regarding the effect of diabetes mellitus (DM) on the risks of both appropriate and inappropriate implantable cardioverter defibrillator (ICD) therapy. The present study was designed to compare the outcome of appropriate and inappropriate ICD therapy in patients with or without DM. METHODS AND RESULTS The risk of a first appropriate ICD therapy for ventricular tachyarrhythmias (including anti tachycardia pacing and shock) was compared between 764 DM and 1346 non-DM patients enrolled in the national Israeli ICD registry. We also compared the risks of inappropriate ICD therapy, and death or cardiac hospitalization between diabetic and non-diabetic patients. Diabetic patients were older, were more likely to have ischemic cardiomyopathy, lower ejection fraction, atrial fibrillation, and other co-morbidities. The 3-year cumulative incidence of appropriate ICD therapy was similar in the DM and non-DM groups (12 and 13%, respectively, p = 0.983). Multivariate analysis showed that DM did not affect the risk of appropriate ICD therapy (HR = 1.07, 95% CI 0.78-1.47, p = 0.694) or inappropriate therapy (HR = 0.72, 95% CI 0.42-1.23, p = 0.232). However, DM was associated with a 31% increased risk for death or cardiac hospitalization (p = 0.005). Results were similar in subgroup analyses including ICD and defibrillators with cardiac resynchronization therapy function recipients, primary or secondary prevention indication for an ICD. CONCLUSIONS Despite a significant excess of cardiac hospitalizations and mortality in the diabetic population, there was no difference in the rate of ICD treatments, suggesting that the outcome difference is not related to arrhythmias.
منابع مشابه
THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملThe effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)
Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملتأثیر آموزش مبتنی بر الگوی خودمراقبتی اورم بر توان خودمراقبتی بیماران دارای دفیبریلاتور قلبی قابل کاشت (ICD)
Background & Aim: Several studies have shown that the self-care activity of patients with implantable cardioverter defibrillator is inadequate. This study was conducted to assess the effect of an educational program based on the Orem’s self-care model in self-care ability of the patients . Methods & Materials: This clinical trial was conducted among 66 patients with implantable cardiove...
متن کاملSex differences in implantable cardioverter-defibrillator implantation indications and outcomes: lessons from the Nationwide Israeli-ICD Registry.
AIMS Implantable cardioverter-defibrillators (ICDs) improve survival in certain high arrhythmic risk populations. However, there are sex differences regarding both the utilization and the benefit of these devices. Using a prospective national ICD registry, we aim to compare the indications for ICD implantation as well as outcomes in implanted women vs. men. METHODS AND RESULTS All subjects im...
متن کامل