Identification and quantitation by high-performance liquid chromatography of mancozeb following derivatization by 1,2-benzenedithiol.

نویسندگان

  • Ikram Debbarh
  • Karine Titier
  • Evelyne Deridet
  • Nicholas Moore
چکیده

Ethylenebisdithiocarbamate (EBDC) fungicides are the most important class of organic fungicides and exhibit a high degree of carcinogenicity, mutagenicity, and neurotoxicity. For that reason, the safe application of these fungicides in practice requires a convenient method for their determination, applicable to biological fluids. We describe a high-performance liquid chromatography (HPLC) assay. After elimination of the metal which defines the product (maneb, mancozeb, zineb.) with EDTA, the resulting EBDC is derivatized with 1,2-benzenedithiol to yield a cyclocondensation product, 1,3-benzodithiole-2-thione, which can then be quantitated by reversed-phase HPLC at 365 nm using a microBondapak C18 column. The mobile phase was methanol/H2O (70:30, v/v). The assay was linear from 0.25 to 100 microg/mL. Within- and between-day precision and accuracy for this assay were better than 9% and 6%, respectively. The lower limits of detection and quantitation were estimated to be 0.1 and 0.25 microg/mL, respectively. This simple new method has been applied to determine mancozeb concentration in rat urine samples from urinary excretion studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat

Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...

متن کامل

High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat

Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...

متن کامل

Determination of Astaxanthin in Trout by High Performance Liquid Chromatography Coupled with Visible Detection

Background: Astaxanthin is widely and naturally distributed in marine animals including, crustaceans, such as shrimp, crabs, and fish, such as salmon and trout. Methods: A total of 20 trout samples were collected from local market and were analyzed for astaxanthin via HPLC-UV. Analyte extraction was done by water, methanol, dichloromethane, and acetonitrile 4.5:85:5:45.5, v/v/v/v. Results: Desp...

متن کامل

Simple and sensitive high performance liquid chromatographic method for the simultaneous quantitation of the phenylalanine in human plasma

Phenylalanine (Phe) is the most reliable indicator for the diagnosis of phenylketonuria (PKU). The purpose of this study is to establish a reliable and quick method for the assignment of Phe in peripheral capillary blood from newborns and children by high performance liquid chromatography with ultraviolet detection (HPLC-UV). PKU is an inborn error of metabolism characterized by the inability o...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 28 1  شماره 

صفحات  -

تاریخ انتشار 2004