Effect of cardiac resynchronization therapy with implantable cardioverter defibrillator versus cardiac resynchronization therapy with pacemaker on mortality in heart failure patients: results of a high-volume, single-centre experience

نویسندگان

  • Valentina Kutyifa
  • Laszlo Geller
  • Peter Bogyi
  • Endre Zima
  • Mehmet K Aktas
  • Emin Evren Ozcan
  • David Becker
  • Vivien Klaudia Nagy
  • Annamaria Kosztin
  • Szabolcs Szilagyi
  • Bela Merkely
چکیده

AIMS There are limited and contradictory data on the effects of CRT with implantable cardioverter defibrillator (CRT-D) on mortality as compared with CRT with pacemaker (CRT-P). METHODS AND RESULTS We evaluated the long-term outcome of patients implanted with a CRT-D or CRT-P device in our high-volume single-centre experience. Data on all-cause mortality were derived from clinic visits and the Hungarian National Healthcare Fund Death Registry. Kaplan-Meier survival analyses and multivariate Cox regression models were used to evaluate all-cause mortality in patients with CRT-D vs. CRT-P, stratified by the aetiology of cardiomyopathy. From 2000 to 2011, 1122 CRT devices, 693 CRT-P (LVEF 28.2 ± 7.4%) and 429 CRT-D (LVEF 27.6 ± 6.4%), were implanted at our centre. During the median follow-up of 28 months, 379 patients died from any cause, 250 patients (36%) with an implanted CRT-P and 129 patients (30%) with an implanted CRT-D. There was no evidence of mortality benefit in patients implanted with a CRT-D compared with a CRT-P in the total cohort [hazard ratio (HR) 0.98, 95% confidence interval (CI) 0.73-1.32, P = 0.884]. In patients with ischaemic cardiomyopathy, CRT-D treatment was associated with a significant 30% risk reduction in all-cause mortality compared with an implanted CRT-P (HR 0.70, 95% CI 0.51-0.97, P = 0.03). In non-ischaemic patients, there was no mortality benefit of CRT-D over CRT-P (HR 0.98, 95% CI 0.73-1.32, P = 0.894, interaction P-value = 0.15). CONCLUSIONS In heart failure patients with ischaemic cardiomyopathy, CRT-D was associated with a mortality benefit compared with CRT-P, but no benefit of CRT-D over CRT-P in mortality was observed in non-ischaemic cardiomyopathy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heart Failure Effect of Cardiac Resynchronization Therapy on Reverse Remodeling and Relation to Outcome Multicenter Automatic Defibrillator Implantation Trial: Cardiac Resynchronization Therapy

Background—Cardiac resynchronization therapy (CRT) plus implantation of an implantable cardioverter defibrillator (ICD) reduced the risk of death or heart failure event in patients with mildly symptomatic heart failure, left ventricular dysfunction, and wide QRS complex compared with an ICD only. We assessed echocardiographic changes in patients enrolled in the MADIT-CRT trial (Multicenter Auto...

متن کامل

Cardiac Resynchronization Therapy Reduces Ventricular Arrhythmias in Primary but Not Secondary Prophylactic Implantable Cardioverter Defibrillator Patients

Cardiac resynchronization defibrillators have been demonstrated to reduce both mortality and heart failure in patients with significant ventricular dysfunction and widened QRS. The influence of cardiac resynchronization therapy (CRT) on ventricular arrhythmias, however, is less certain. A systematic review of randomized controlled trials of more advanced heart failure populations with New York ...

متن کامل

Cardiac Resynchronization Therapy for Heart Failure

The weight of evidence supporting the routine use of cardiac resynchronization therapy, or atrial-synchronized biventricular pacing, as a treatment for patients with moderate-to-severe chronic systolic heart failure and ventricular dyssynchrony is now quite substantial. Results from mechanistic studies, observational evaluations, and randomized, controlled trials have consistently demonstrated ...

متن کامل

Effects of Upgrade Versus De Novo Cardiac Resynchronization Therapy on Clinical Response and Long-Term Survival

The beneficial impact of newly implanted cardiac resynchronization therapy (CRT) on morbidity and mortality are well described in selected patients with heart failure. Patients with heart failure already fitted with a conventional pacemaker or implantable cardioverter defibrillator (ICD) system are often considered for a CRT upgrade after the new development of CRT criteria (ie, new left bundle...

متن کامل

Medical Treatment of Heart Failure with Reduced Ejection Fraction – Aimed at Reducing Re- hospitalisations

Introduction The prognosis of patients with heart failure has significantly improved in the past decades with the advent of therapies such as angiotensinconverting enzyme (ACE) inhibitors, betablockers, mineralocorticoid receptor antagonists (MRAs), ivabradine, LCZ696 and with devices such as implantable cardioverterdefibrillator (ICD) and cardiac resynchronization therapy devices (CRT).[1] By ...