Direct chemiluminescence immunoassay for estradiol in serum.
نویسندگان
چکیده
In this simple, reliable, fast solid-phase chemiluminescence immunoassay for directly measuring (i.e., without prior extraction) estradiol-17 beta in serum, a monoclonal antibody is used that binds estradiol with high affinity (Ka = 10(10) L/mol), and does not bind other steroids tested, the highest cross reactivity observed being 0.1% for estradiol-17 alpha. In this system the monoclonal antibody is bound to the wells of microtiter plates via a second antibody directed against the monoclonal antibody. Fifty microliters of serum and estradiol-displacing agents are added, followed by 100 pg of estradiol-isoluminol conjugate, and the label is measured by luminometry after the binding reaction. The sensitivity of the assay is 180 pmol per liter of serum, and the effective working range at less than or equal to 10% CV is 270 to 6700 pmol/L. Analytical recovery of added estradiol averaged 99.7% (SD 6.5%). Within- and between-assay CVs ranged between 5 and 12.7%. Thirty-five unknown serum samples can be assayed within 4 h. Results correlated well with those obtained with a direct RIA: r = 0.94 (n = 149). This assay opens new perspectives for chemiluminescence immunoassays.
منابع مشابه
Direct chemiluminescence immunoassay of estradiol in saliva.
A sensitive and simple direct solid-phase chemiluminescence immunoassay is described for estradiol in saliva. In this assay, a second antibody is bound to the wells of microtiter plates. Either buffer with standards or saliva (100 microL) is incubated in these wells with monoclonal anti-estradiol antibody and with estradiol-isoluminol conjugate. Incubation time is 2 h. Chemiluminescence of the ...
متن کاملMeasurement of plasma estradiol-17 beta by solid-phase chemiluminescence immunoassay.
We describe a simple, solid-phase chemiluminescence immunoassay for the measurement of estradiol-17 beta in extracts of peripheral venous plasma. The method has similar sensitivity, specificity, precision, and accuracy to a conventional radioimmunoassay with a tritiated antigen. An immunoglobulin G fraction od monoclonal antibodies to estradiol-6-carboyxmethyl oxime-bovine serum albumin is pass...
متن کاملIntroducing chemiluminescence resonance energy transfer into immunoassay in a microfluidic format for an improved assay sensitivity.
We report on a novel strategy to improve microfluidic immunoassay sensitivity by introducing chemiluminescence resonance energy transfer (CRET) into the immunoreactions. The proposed CRET-based immunoassay for estradiol (E2, as a model analyte) is one of the most sensitive immunoassay with a limit of detection at 3.6 × 10(-11) M E2 in a microfluidic format.
متن کاملSolid-phase chemiluminescence immunoassay for progesterone in unextracted serum.
We describe a simple, solid-phase chemiluminescence immunoassay for progesterone in 10 microL of unextracted serum ("direct" assay). Danazol at pH 8.0 is included (100 ng per tube) to displace progesterone from binding proteins in serum. A progesterone-11 alpha-hemisuccinyl-aminobutylethyl isoluminol conjugate serves as the chemiluminescent ligand marker and homologous antiprogesterone IgG cova...
متن کاملVariations of serum estradiol and progesterone levels during consecutive reproductive states in Mongolian gerbils (Meriones unguiculatus).
Serum estradiol (E2) and progesterone (P4) levels were measured by chemiluminescence immunoassay (CLIA) during consecutive reproductive states in Mongolian gerbils. The results show that E2 and P4 levels throughout the estrous cycle in Mongolian gerbils peaked at proestrus and estrus, respectively. During gestation in primiparous and multiparous gerbils, E2 levels reached a small peak on day 6 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 32 10 شماره
صفحات -
تاریخ انتشار 1986