Spatial distribution of electrical reconnection after pulmonary vein isolation in patients with recurrent paroxysmal atrial fibrillation
نویسندگان
چکیده
INTRODUCTION Recurrence of atrial fibrillation after pulmonary vein isolation (PVI) occurs frequently and may be associated with electrical reconnection of the pulmonary veins (PV). We investigated spatial distribution of electrical reconnection during re-do procedures in patients with paroxysmal atrial fibrillation who had previous successful acute electrical PVI with either single irrigated tip, antral ablation (s-RF; n = 38) or multi-electrode, duty-cycled ablation (PVAC; n = 48). METHODS AND RESULTS EP navigator, mapping and irrigated tip ablation catheters were used in all re-do procedures. Sites of reconnection were assessed in a 12-segment model. Baseline clinical and demographic characteristics were similar in both groups. The number of PVs reconnected per patient was similar in both groups (2.9 ± 0.9 and 3.2 ± 0.7 (p = 0.193), s‑RF and PVAC, respectively), and each PV was equally affected. However, the inferior quadrant of the right lower PV was significantly more vulnerable to reconnection after previous PVAC ablation, whereas the superior quadrant of the right upper PV showed significantly more reconnection in the s‑RF group. CONCLUSION The overall number of PVs reconnected was equally high in both groups, and each PV was affected equally. However, there were significant differences in the spatial distribution of electrical reconnection. Better understanding of predilection sites for reconnection might help to improve the long-term success rate of PVI.
منابع مشابه
Clinical implication of adenosine test at repeat atrial fibrillation ablation procedure: the importance of detecting dormant thoracic vein conduction.
BACKGROUND Pulmonary vein reconnection after electrical isolation is commonly observed in the context of atrial fibrillation ablation and is associated with recurrent atrial tachyarrhythmias. Adenosine test was been performed to identify acute dormant conduction immediately after pulmonary vein isolation at index procedure. However, the utility of adenosine test at repeat procedure has not been...
متن کاملEarly Pulmonary Vein Conduction Recovery after Catheter Ablation of Atrial Fibrillation.
Background Pulmonary vein electrical isolation (PVI) is an effective treatment for atrial fibrillation (AF). However, recurrence of pulmonary vein (PV) conduction after ablation may limit long-term success. Early identification and treatment of acute PV conduction recovery during initial ablation may have an impact on subsequent clinical results. Objective To assess the prevalence of acute PV...
متن کاملChallenges and Outcomes of Posterior Wall Isolation for Ablation of Atrial Fibrillation
BACKGROUND The left atrial posterior wall (PW) often contains sites required for maintenance of atrial fibrillation (AF). Electrical isolation of the PW is an important feature of all open surgeries for AF. This study assessed the ability of current ablation techniques to achieve PW isolation (PWI) and its effect on recurrent AF. METHODS AND RESULTS Fifty-seven consecutive patients with persi...
متن کاملComplete pulmonary vein isolation using balloon cryoablation in patients with paroxysmal atrial fibrillation.
Electrical isolation of the pulmonary veins and disconnection of the left atrial musculature from their arrhythmogenic effects is the cornerstone of definitive and curative treatment in patients with symptomatic recurrent paroxysmal atrial fibrillation that is refractory to antiarrhythmic therapy. The type of lesion produced by balloon cryoablation is such that the tissue architecture is preser...
متن کاملAtrial scar on late gadolinium-enhanced imaging to predict electrical reconnection after pulmonary vein isolation for atrial fibrillation
Methods LGE CMR was performed 3 months after PVI in 24 patients with paroxysmal AF (age 62 ± 9 years, 4 women). Imaging was performed 15 min after contrast in transaxial and sagital orientations using an inversion-recovery prepared and respiratory navigated 3D turboFLASH sequence with fat saturation (pixel size 1.25 × 1.25 × 2.5 mm). Scar burden (mL) was quantified on transaxial images using ad...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 24 شماره
صفحات -