'Focused workshop on Region of Interest X-ray Computed Tomography' held on 17-20 November 2015 at Elettra (Trieste, Italy)
نویسنده
چکیده
To satisfy the heterogeneous needs of X-ray CT users, flexible solutions are required both from the hardware and software point of view. The use of synchrotrons and microfocus X-ray sources present complementary approaches being characterized by different properties in terms of achievable spatial resolution, field of view and image contrast. The main aim of this event was to bring together experimentalists, mathematicians and computing scientists and explore this specific topic in Computed Tomography (CT) data collection and reconstruction. This focused meeting hosted a small group of mathematicians and computational scientists at the Elettra Sincrotrone Trieste laboratory (Italy) with the aim to study in detail the Region-Of-Interest (ROI) problem in CT. This workshop has been organized as a follow-up of the Lorentz 2015 workshop focusing our attention on the specific topic of ROI-CT. In fact, ROI-CT reconstructed images are often corrupted by artefacts that, in some cases, mask part of the information contained in the image itself. Find solutions require a full comprehension of the origin of these artefacts. Micro-CT data were analyzed on site having the ability to acquire the data at varying contrast and spatial resolutions and on different instruments. The whole object has been imaged at medium spatial resolution by using a conventional CT instrument based on a microfocus source (http://www.elettra.trieste.it/li ) and then a selected ROI has been selected and imaged at higher spatial resolution. A similar ghtsources/labs-and-services/tomolab/tomolab.html approach has been adopted at the SYRMEP beamline of Elettra ( ) where a micro-CT http://www.elettra.trieste.it/elettra-beamlines/syrmep.html instrument allowing to work at higher spatial resolution and based on a synchrotron source is available. A mixed approach employing the conventional and synchrotron sources for the same object has been also explored.
منابع مشابه
An IAEA multi-technique X-ray spectrometry endstation at Elettra Sincrotrone Trieste: benchmarking results and interdisciplinary applications.
The International Atomic Energy Agency (IAEA) jointly with the Elettra Sincrotrone Trieste (EST) operates a multipurpose X-ray spectrometry endstation at the X-ray Fluorescence beamline (10.1L). The facility has been available to external users since the beginning of 2015 through the peer-review process of EST. Using this collaboration framework, the IAEA supports and promotes synchrotron-radia...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملPhase-contrast computed tomography for quantification of structural changes in lungs of asthma mouse models of different severity
Lung imaging in mouse disease models is crucial for the assessment of the severity of airway disease but remains challenging due to the small size and the high porosity of the organ. Synchrotron inline free-propagation phase-contrast computed tomography (CT) with its intrinsic high soft-tissue contrast provides the necessary sensitivity and spatial resolution to analyse the mouse lung structure...
متن کاملGlandular dose in breast computed tomography with synchrotron radiation.
The purpose of this work is to provide an evaluation of the mean glandular dose (MGD) for breast computed tomography (CT) with synchrotron radiation in an axial scanning configuration with a partial or total organ volume irradiation, for the in vivo program of breast CT ongoing at the ELETTRA facility (Trieste, Italy). A Geant4 Monte Carlo code was implemented, simulating the photon irradiation...
متن کاملImpact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کامل