Evaluation of the "Auto-Stat 6010" automatic osmometer and its comparison with the "digimatic-advanced 3DII" manual osmometer.

نویسندگان

  • M A Elorza
  • A Garcia
  • A Fuster
  • A Muller
چکیده

The results are presented of a comparative study between two osmometers, a manual one, Digimatic-Advanced 3DII (Advanced Instruments, Medical Europa, Barcelona), and an automatic one, Auto-Stat 6010 (Kyoto, Daiichi, Kagaku, Menarini, Firenze). Both osmometers have the same operation principle, but they employ different systems for determination of the freezing point depression. Both instruments showed good precision (CV < 1%), accuracy, and a wide range of linearity. In the assay of 133 sera and 101 24-h urines, the methods showed a good correlation (r = 0.945 and r = 0.999) and the Anova test showed no statistical difference between the means (p > 0.05). The carry over effect in the Auto-Stat was statistically significant (p < 0.001) but within the range of imprecision of the osmometers. Variation due to evaporation is lower than 0.8%. In conclusion, we are sure that both osmometers are useful in the laboratory, although the Auto-Stat 6010 osmometer has the advantage over the Digimatic-Advanced 3DII of automatic sample processing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cell culture monitoring via an auto-sampler and an integrated multi-functional off-line analyzer.

Mammalian cell-based bioprocesses are used extensively for production of therapeutic proteins. Off-line monitoring of such cultivations via manual sampling is often labor-intensive and can introduce operator-dependent error into the process. An integrated multi-functional off-line analyzer, the BioProfile FLEX (NOVA Biomedical, Waltham MA) has been developed, which combines the functionality of...

متن کامل

An evaluation of osmolality measurement by freezing point depression using micro-amounts of sample

An evaluation of the Advanced micro-osmometer is presented. This instrument has been shown to have an excellent analytical precision (within-run CV = 0.59%, between-day CV = 0.58%). It is accurate over an analytical range of 0-2000 mmol/kg of osmolality shown by linearity studies and split sample correlations against vapour pressure osmometry, freezing point osmometry and an external quality as...

متن کامل

A Convenient Small Osmometer

A description is given of a simple, rugged instrument for determining the osmotic pressure developed by a solution of a high polymer. Other small osmometers described previously [1, 2, 3, 4, 5]/ have been, in some respects, too inconvenient to use. Although relatively easy to make, glass osmometers are fragile and may require frequent repairs. Small metal osmometers, in addition to being rugged...

متن کامل

[Comparison of two osmometers at the clinical chemistry laboratory].

Measurement of osmolality and calculation of osmolar gap are useful diagnostic tools in pathological situations such as hyponatremia, or intoxication by methanol or ethylene glycol. It is thus necessary to handle reliable systems of osmolality measurement. The aim of this study was to compare performances of two currently available osmometers, Fiske 210 and Advanced 3300 devices, both of them b...

متن کامل

Electronic osmometer with rigid membrane of copper ferrocyanide.

greatly reduced the amount of the sample solution and the measuring time.1-3 However, the electronic osmometers reported to date are in use of flaccid mem branes which result in baseline instability and limit the use to low con centrations of colloid solute in solutions. Recently, we have designed an electronic osmometer with a rigid semiperme able membrane made from a baked clay disc permeated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies

دوره 31 4  شماره 

صفحات  -