Compressed sensing to accelerate magnetic resonance spectroscopic imaging: evaluation and application to 23Na-imaging of mouse hearts
نویسندگان
چکیده
BACKGROUND Magnetic Resonance Spectroscopic Imaging (MRSI) has wide applicability for non-invasive biochemical assessment in clinical and pre-clinical applications but suffers from long scan times. Compressed sensing (CS) has been successfully applied to clinical 1H MRSI, however a detailed evaluation of CS for conventional chemical shift imaging is lacking. Here we evaluate the performance of CS accelerated MRSI, and specifically apply it to accelerate 23Na-MRSI on mouse hearts in vivo at 9.4 T. METHODS Synthetic phantom data representing a simplified section across a mouse thorax were used to evaluate the fidelity of the CS reconstruction for varying levels of under-sampling, resolution and signal-to-noise ratios (SNR). The amplitude of signals arising from within a compartment, and signal contamination arising from outside the compartment relative to noise-free Fourier-transformed (FT) data were determined. Simulation results were subsequently verified experimentally in phantoms and in three mouse hearts in vivo. RESULTS CS reconstructed MRSI data are scaled linearly relative to absolute signal intensities from the fully-sampled FT reconstructed case (R(2) > 0.8, p-value < 0.001). Higher acceleration factors resulted in a denoising of the reconstructed spectra, but also in an increased blurring of compartment boundaries, particularly at lower spatial resolutions. Increasing resolution and SNR decreased cross-compartment contamination and yielded signal amplitudes closer to the FT data. Proof-of-concept high-resolution, 3-fold accelerated 23Na-amplitude maps of murine myocardium could be obtained within ~23 mins. CONCLUSIONS Relative signal amplitudes (i.e. metabolite ratios) and absolute quantification of metabolite concentrations can be accurately determined with up to 5-fold under-sampled, CS-reconstructed MRSI. Although this work focused on murine cardiac 23Na-MRSI, the results are equally applicable to other nuclei and tissues (e.g., 1H MRSI in brain). Significant reduction in MRSI scan time will reduce the burden on the subject, increase scanner throughput, and may open new avenues for (pre-) clinical metabolic studies.
منابع مشابه
Accelerating Magnetic Resonance Imaging through Compressed Sensing Theory in the Direction space-k
Magnetic Resonance Imaging (MRI) is a noninvasive imaging method widely used in medical diagnosis. Data in MRI are obtained line-by-line within the K-space, where there are usually a great number of such lines. For this reason, magnetic resonance imaging is slow. MRI can be accelerated through several methods such as parallel imaging and compressed sensing, where a fraction of the K-space lines...
متن کاملCompressed Sensing for High-Spatiotemporal Functional Magnetic Resonance Imaging and Its Application of Exploiting Sparsity for Image Denoising
In this project, we apply compressed sensing (CS) technique to achieve high-spatiotemporal functional magnetic resonance imaging (MRI), which is very challenging with conventional approaches due to physical limitations such as slew rate. We also use its ideas of exploiting sparsity for image denoising. Keywords—compressed sensing; MRI; sparsity; image denoising
متن کاملAccelerating cine-MR Imaging in Mouse Hearts Using Compressed Sensing
PURPOSE To combine global cardiac function imaging with compressed sensing (CS) in order to reduce scan time and to validate this technique in normal mouse hearts and in a murine model of chronic myocardial infarction. MATERIALS AND METHODS To determine the maximally achievable acceleration factor, fully acquired cine data, obtained in sham and chronically infarcted (MI) mouse hearts were 2-4...
متن کاملAccelerating phase-encoded proton MR spectroscopic imaging by compressed sensing.
PURPOSE To develop a phase encoding reduction scheme based on compressed sensing (CS) for phase-encoded (1) H MR spectroscopic imaging (MRSI). MATERIALS AND METHODS Phantom and in vivo rat brain MRSI experiments were performed at 7 Tesla to examine the performance of CS approach and compare it with the full k-space acquisition. The CS undersampling was performed by acquiring a pseudorandom an...
متن کاملAccelerated Proton Echo-Planar Spectroscopic Imaging Using Parallel Imaging and Compressed Sensing
INTRODUCTION: Proton Echo-Planar Spectroscopic Imaging (PEPSI) provides fast spatial-spectral encoding and has been demonstrated to map a variety of metabolites in the human brain [1,2]. Further acceleration in PEPSI can be accomplished by using parallel imaging along the phaseencoding dimension(s) [3,4]. However, the acceleration is limited by the relatively low SNR of the metabolites and g-fa...