Elemental speciation by parallel elemental and molecular mass spectrometry and peak profile matching.

نویسندگان

  • Gavin L Sacks
  • Louis A Derry
  • J Thomas Brenna
چکیده

Trace elemental speciation in complex, real-world matrixes is a daunting task because of the low concentration of metals/metalloids and the correspondingly high molecular chemical noise. We constructed a liquid chromatography parallel elemental and molecular mass spectrometry (PEMMS) system and evaluated the use of peak elution profiles to identify trace molecular species containing specific heteroatoms, using the case of Se in yeast. We demonstrate that it is possible to use the HPLC-inductively coupled plasma (ICP)MS peak profile (retention time, width) to identify candidate ions with matching peak profiles in the molecular MS data. Proof of principle was demonstrated by C18 separation of three Se-amino acid standards (0.005-15 ppm as Se). The molecular MS (atmospheric pressure chemical ionization time-of-flight, APCI-TOF-MS) data set was converted into selected ion chromatograms of 0.05 Th width. ICPMS and APCI-TOF-MS ion chromatograms were fit by the Haarhoff-VanderLinde function using the following parameters: area, retention time, width, and skew. The ICPMS fit parameters were more reproducible than the APCI-TOF-MS fit parameters from run to run, and the APCI-TOF-MS signal was expected to limit correlation in most circumstances. Retention time and width were found to correlate well between the two MS systems for APCI-TOF-MS peaks with signal-to-fit-error (S/FE) of >25. Correction factors for differences in flow path length and peak broadening were required. The normalized correction factors were species and concentration independent and were stable from run to run. The skew parameter was found to be highly susceptible to noise and was not generally useful in matching ICPMS and APCI-TOF-MS peaks. An artificially noisy sample was generated by spiking 30 ppb Se-methionine (SeMet) and 5 ppb Se-methylselenocysteine (SeMSC) with unselenized yeast extract and run by PEMMS. The PEMMS software was able to detect four molecular MS peaks associated with SeMet and two for SeMSC, while filtering out >40 coeluting spectral peaks associated with chemical noise in each sample. In summary, we have demonstrated that correlated information in peak shape between parallel detectors can facilitate detection of trace elemental species in complex matrixes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Elemental speciation: where do we come from? where do we go?{

The present day status of elemental speciation is largely based on the use of hyphenated techniques in particular in the combination of various types of chromatography with inductively coupled plasma mass spectrometry. The present status of environmental speciation with the hyphenated techniques is reviewed. There is a growing need for more comprehensive approaches including the direct analysis...

متن کامل

Speciation studies of vanadium in human liver (HepG2) cells after in vitro exposure to bis(maltolato)oxovanadium(IV) using HPLC online with elemental and molecular mass spectrometry.

A large number of studies has been published proposing a range of vanadium containing compounds as potential new anti-diabetic drugs due to the observed insulin mimetic function of V(IV) complexes. Vanadium uptake and distribution within the body have been investigated in animal models by determination of total vanadium concentrations. Phase I and phase IIa human clinical trials have been compl...

متن کامل

Gas chromatography/plasma spectrometry—an important analytical tool for elemental speciation studies

In this review, a full discussion and update of the state-of-the-art of gas chromatography (GC) coupled to all known plasma spectrometers is presented. A brief introductive discussion of the advantages and disadvantages of GC–plasma interfaces, as well as types of plasmas and mass spectrometers, is given. The plasma-based techniques covered include inductively coupled plasma mass spectrometry (...

متن کامل

Analytical atomic spectrometry going into the next millennium: photons or ions, atoms or molecules?†

Analytical atomic spectrometry seems to be suffering a sort of ‘identity crisis’ at the sunset of this millennium. The field has undergone profound changes and the rate of change has increased dramatically in the last decade. For many years the main goal of analytical atomic spectrometry was to provide atomic/elemental information on the composition of matter via the development of spectrochemi...

متن کامل

Speciation and isotope pattern deconvolution for inductively coupled plasma-mass spectrometry quantitative studies of mineral metabolism and supplementation*

Human breast milk can be considered as “ideal” food for the correct development of newborn babies and, for those that are not breast-fed, formula milk has to be used instead. Ideally, the composition of such formula milk preparations should closely resemble that of maternal human milk. Considerable differences between both in the total content of trace elements such as Fe, Cu, Se, Zn, and I and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 78 24  شماره 

صفحات  -

تاریخ انتشار 2006