Radioactive 133-Xenon gas-filled balloon to prevent restenosis: dosimetry, efficacy, and safety considerations.
نویسندگان
چکیده
BACKGROUND Ionizing radiation administered intraluminally via catheter-based systems using solid beta and gamma sources or liquid-filled balloons has shown reduction in the neointima formation after injury in the porcine model. We propose a novel system that uses a 133-Xenon (133Xe) radioactive gas-filled balloon catheter system. METHODS AND RESULTS Overstretch balloon injury was performed in the coronary arteries of 33 domestic pigs. A novel 133Xe radioactive gas-filled balloon (3.5/45 mm) was positioned to overlap the injured segment with margins. After vacuum was obtained in the balloon catheter, approximately 2.5 cc of 133Xe gas was injected to fill the balloon. Doses of 0, 7.5, 15, and 30 Gy were delivered to a distance of 0.25 mm from the balloon surface. The dwell time ranged from 1.0 to 4.0 minutes, depending on the dose. Localization of 133Xe in the balloon was verified by a gamma camera. The average activity in a 3.5/45-mm balloon was measured at 67.7+/-12.1 mCi, and the total diffusion loss of the injected dose was 0.26% per minute of the injected dose. Bedside radiation exposure measured between 2 and 6 mR/h, and the shallow dose equivalent was calculated as 0.037 mrem per treatment. Histomorphometric analysis at 2 weeks showed inhibition of the intimal area (intimal area corrected for medial fracture length [IA/FL]) in the irradiated segments of 0.26+/-0.08 with 30 Gy, 0.07+/-0.24 with 15 Gy, and 0.12+/-0.89 with 7.5 Gy versus 0.76+/-0.08 with control P<0.001. CONCLUSIONS 133Xe gas-filled balloon is feasible and effective in the reduction of neointima formation in the porcine model and safe for use in coronary arteries.
منابع مشابه
Radioactive 133-Xenon Gas-Filled Balloon to Prevent Restenosis
Background—Ionizing radiation administered intraluminally via catheter-based systems using solid and sources or liquid-filled balloons has shown reduction in the neointima formation after injury in the porcine model. We propose a novel system that uses a 133-Xenon (Xe) radioactive gas-filled balloon catheter system. Methods and Results—Overstretch balloon injury was performed in the coronary ar...
متن کاملDosimetry of 188Re and 186Re sources based on Monte Carlo calculations for endovascular brachytherapy after balloon angioplasty
Background: Recent pre-clinical and clinical studies indicate that irradiation in the dose range of 15 to 30 Gy can reduce rate of restenosis in patients who have undergone an angioplasty. The use of filled balloon with radioactive solution was proposed as one of the possible intravascular irradiation techniques. Materials and Methods: The Monte Carlo N-particle Transport Code (MCNP4b) was used...
متن کاملA novel balloon angioplasty catheter impregnated with beta-particle emitting radioisotopes for vascular brachytherapy to prevent restenosis; first in vivo results.
BACKGROUND According to early clinical trials, vascular brachytherapy performed prior to or shortly after angioplasty is very effective in reducing restenosis rates. The purpose of this study was to investigate the effects of a novel radioactive catheter that allows simultaneous balloon angioplasty and beta-particle irradiation in the prevention of restenosis. MATERIAL AND METHODS The balloon...
متن کاملDosimetry of 188Re and 186Re sources based on Monte Carlo calculations for endovascular brachytherapy after balloon angioplasty
R ecent pre-clinical and clinical studies indicate that irradiation within the dose range of 15 to 30 Gy can reduce the rate of restenosis in patients who have undergone an angioplasty (Nath 1999, King 1998). Several delivery systems of intravascular brachytherapy have been developed to deliver doses within this rang with minimal normal tissue toxicity. One of the possible intravascular irradia...
متن کاملPreparation of Xenon-133 Solution for Intravenous Administration
A method for routine preparation of a solution of 133 Xe gas in saline from commercially available m Xe gas ampoules is described and evaluated. At room temperature and atmospheric pressure, about 25% of the mxe gas dissolves in saline. Xenon-133 binds to the syringe wall or may escape into the air when stored in sealed plastic syringes. Preparation immediately prior to use, short-term storage ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 106 6 شماره
صفحات -
تاریخ انتشار 2002