Are there sex differences in the capillary blood volume and diffusing capacity response to exercise?

نویسندگان

  • Melissa M Bouwsema
  • Vincent Tedjasaputra
  • Michael K Stickland
چکیده

Previous work suggests that women may exhibit a greater respiratory limitation in exercise compared with height-matched men. Diffusion capacity (DlCO) increases with incremental exercise, and the smaller lungs of women may limit membrane diffusing capacity (Dm) and pulmonary capillary blood volume (Vc) in response to the increased oxygen demand. We hypothesized that women would have lower DlCO, DlCO relative to cardiac output (DlCO/Q̇), Dm, Vc, and pulmonary transit time, secondary to lower Vc at peak exercise. Sixteen women (112 ± 12% predicted relative V̇o2peak) and sixteen men (118 ± 22% predicted relative V̇o2peak) were matched for height and weight. Hemoglobin-corrected diffusing capacity (DlCO), Vc, and Dm were determined via the multiple-[Formula: see text] DlCO technique at rest and during incremental exercise up to 90% of V̇o2peak Both groups increased DlCO, Vc, and Dm with exercise intensity, but women had 20% lower DlCO (P < 0.001), 18% lower Vc (P = 0.002), and 22% lower Dm (P < 0.001) compared with men across all workloads, and neither group exhibited a plateau in Vc. When expressed relative to alveolar volume (Va), the between-sex difference was eliminated. The drop in DlCO/Q̇ was proportionally less in women than men, and mean pulmonary transit time did not drop below 0.3 s in either group. Women demonstrate consistently lower DlCO, Vc, and Dm compared with height-matched men during exercise; however, these differences disappear with correction for lung size. These results suggest that after differences in lung volume are accounted for there is no intrinsic sex difference in the DlCO, Vc, or Dm response to exercise.NEW & NOTEWORTHY Women demonstrate lower diffusing capacity-to-cardiac output ratio (DlCO/Q̇), pulmonary capillary blood volume (Vc), and membrane diffusing capacity (Dm) compared with height-matched men during exercise. However, these differences disappear after correction for lung size. The drop in DlCO/Q̇ was proportionally less in women, and pulmonary transit time did not drop below 0.3 s in either group. After differences in lung volume are accounted for, there is no intrinsic sex difference in DlCO, Vc, or Dm response to exercise.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of aerobic fitness on capillary blood volume and diffusing membrane capacity responses to exercise

KEY POINTS Endurance trained athletes exhibit enhanced cardiovascular function compared to non-athletes, although it is considered that exercise training does not enhance lung structure and function. An increased pulmonary capillary blood volume at rest is associated with a higher V̇O2 max . In the present study, we compared the diffusion capacity, pulmonary capillary blood volume and diffusing ...

متن کامل

Effect of lung inflation on pulmonary diffusing capacity at rest and exercise.

Steady state measurements of the diffusing capacity of the lung are made at operational lung volume, whereas measurements by the breath-holding method are customarily made at full inspiration. The effect of lung inflation on diffusing capacity must be taken into account before the steady state and breath-holding methods can be validly compared. At rest the single breath diffusing capacity of th...

متن کامل

Pulmonary membrane diffusing capacity and capillary blood volume in tropical eosinophilia.

Pulmonary membrane diffusing capacity (Dm) and pulmonary capillary blood volume (Vc) measurements were carried out in 21 patients with untreated tropical eosinophilia and 21 healthy controls matched for age, sex, height, and smoking habit. The mean single breath transfer factor (Dco) and the mean membrane diffusing capacity were significantly lower (p less than 0.001) in patients with tropical ...

متن کامل

Type 1 Diabetes Duration Decreases Pulmonary Diffusing Capacity during Exercise.

BACKGROUND Diabetes damages peripheral tissues; however, its effects on the lung are less known. Lung diffusing capacity (DLCO) is influenced by alveolar-capillary membrane conductance (DM) and pulmonary capillary blood volume (VC), both of which are reduced in adults with type 1 diabetes (T1D). OBJECTIVE We sought to determine if diabetes duration affects DLCO, DM, VC, and cardiac output (Q)...

متن کامل

Steady-state measurement of NO and CO lung diffusing capacity on moderate exercise in men.

Using a rapidly responding nitric oxide (NO) analyzer, we measured the steady-state NO diffusing capacity (DL(NO)) from end-tidal NO. The diffusing capacity of the alveolar capillary membrane and pulmonary capillary blood volume were calculated from the steady-state diffusing capacity for CO (measured simultaneously) and the specific transfer conductance of blood per milliliter for NO and for C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 122 3  شماره 

صفحات  -

تاریخ انتشار 2017