Presence of Legionella spp. in Hot Water Networks of Different Italian Residential Buildings: A Three-Year Survey

نویسندگان

  • Michele Totaro
  • Paola Valentini
  • Anna Laura Costa
  • Lorenzo Frendo
  • Alessia Cappello
  • Beatrice Casini
  • Mario Miccoli
  • Gaetano Privitera
  • Angelo Baggiani
چکیده

Although the European reports highlight an increase in community-acquired Legionnaires' disease cases, the risk of Legionella spp. in private houses is underestimated. In Pisa (Italy) we performed a three-year survey on Legionella presence in 121 buildings with an independent hot water production (IB); 64 buildings with a central hot water production (CB); and 35 buildings with a solar thermal system for hot water production (TB). From all the 220 buildings Legionella spp. was researched in two hot water samples collected either at the recirculation point or on the first floor and on the last floor, while the potable water quality was analysed in three cold water samples collected at the inlet from the aqueduct network, at the exit from the autoclave, and at the most remote tap. Legionella pneumophila sg1, Legionella pneumophila sg2-16, and non-pneumophila Legionella species were detected in 26% of the hot water networks, mostly in CB and TB. In these buildings we detected correlations between the presence of Legionella and the total chlorine concentration decrease and/or the increase of the temperature. Cold water resulted free from microbiological hazards, with the exception of Serratia liquefaciens and Enterobacter cloacae isolated at the exit from two different autoclaves. We observed an increase in total microbial counts at 22 °C and 37 °C between the samples collected at the most remote taps compared to the ones collected at the inlet from the aqueduct. The study highlights a condition of potential risk for susceptible categories of population and supports the need for measures of risk assessment and control.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

FRONT MATTER Title: Presence of Legionella spp. in hot water networks of different Italian residential buildings: a three-year survey

Although the European reports highlight an increase in community-acquired Legionnaires’ disease cases, the risk of Legionella spp. in private houses is underestimated. In Pisa (Italy) we performed a three-year survey on Legionella presence in 121 buildings with an independent hot water production (IB); 64 buildings with a central hot water production (CB); and 35 buildings with a solar thermal ...

متن کامل

Occurrence of Legionella Pneumophila in Potable Water Supply Systems in Apartment Buildings in Riga and Evaluation of Sampling Strategies

The prevention and control of legionellosis in water supply systems involves environmental comprehensive sampling. Our aim was to investigate occurrence of Legionella spp. in water supply systems in different administrative districts of Riga, and to find out if there exists a correlation between Legionella spp. positive cases and water source, type of sample, sampling point and temperature of h...

متن کامل

Legionella contamination in hot water of Italian hotels.

A cross-sectional multicenter survey of Italian hotels was conducted to investigate Legionella spp. contamination of hot water. Chemical parameters (hardness, free chlorine concentration, and trace element concentrations), water systems, and building characteristics were evaluated to study risk factors for colonization. The hot water systems of Italian hotels were strongly colonized by Legionel...

متن کامل

Isolation and identification of Legionella spp. from different aquatic sources in south-west of Iran by molecular &culture methods

Legionella pneumophila, the causative agent of Legionnaires’ diseases (LD) is usually transmitted to humans via inhalation of aerosols from contaminated natural and manmade water sources. These organisms may become fatal especially in immunocompromised patients and LD is the one of the important disease from a public health perspective. This survey investigated the frequency of Legionella spp. ...

متن کامل

Legionella Infection Risk from Domestic Hot Water

We investigated Legionella and Pseudomonas contamination of hot water in a cross-sectional multicentric survey in Italy. Chemical parameters (hardness, free chlorine, and trace elements) were determined. Legionella spp. were detected in 33 (22.6%) and Pseudomonas spp. in 56 (38.4%) of 146 samples. Some factors associated with Legionella contamination were heater type, tank distance and capacity...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2017