Microbial leakage through the implant-abutment interface of Morse taper implants in vitro.
نویسندگان
چکیده
OBJECTIVES The aim of this study was to determine and compare the frequency of bacterial leakage of Streptococcus sanguinis biotype II along the implant-abutment interface between two systems of morse taper dental implants. Different methods of activation of the taper abutments were used: tapped-in (Bicon) and screwed-in (Ankylos). MATERIALS AND METHODS Twenty sterile assemblies were used and attached, 10 Bicon and 10 Ankylos implants, according to manufacturers' specifications. They were then totally immersed within 20 test tubes containing a sterile nutrient solution brain-heart infusion (BHI). The internal part of the 20 implants was previously inoculated with 0.1 microl of S. sanguinis II (ATCC 10557) and then connected to the respective abutments. The assemblies were incubated under anaerobic conditions for 14 days in an autoclave at 37 degrees C. They were monitored daily for solution cloudiness resultant from microbial leakage on the interface of the assemblies. For statistical analysis, the Fisher test was applied and significance was assigned at the 5% level. RESULTS There was solution cloudiness, indicating the finding of bacterial growth inside two Bicon assemblies and two Ankylos assemblies 48 h after incubation. Microbial leakage was further substantiated by testing the suspension for the presence of Streptococcus sp. None of the sterility controls were contaminated. The frequency of bacterial leakage along the implant-abutment interface, with the two different morse taper implant systems, was 20% of the assemblies of each system. There were no statistical differences between them. CONCLUSION Irrespective of which of the two morse taper implant connection systems of activation was analyzed, tapped-in (Bicon) or screwed-in (Ankylos), this in vitro experiment showed bacterial leakage along the implant-abutment interface.
منابع مشابه
An in vitro investigation concerning the bacterial leakage at implants with internal hexagon and Morse taper implant-abutment connections.
PURPOSE To evaluate, in vitro, the leakage observed in internal hexagon and Morse taper implant-abutment connections. MATERIALS Ten specimens with internal hexagon and 10 with Cone Morse connection were used. The inner parts of 5 implants, per group, were inoculated with Pseudomonas aeruginosa (PS) suspension and 5 implants, per group, with Aggregatibacter actinomycetemcomitans (AA). The pene...
متن کاملBacterial colonization at implant – abutment interface: a systematic review
Background: Although implants have shown to have a high success rate, clinicians are also called upon to encounter numerous complications and failures. Among the numerous reasons of failures, peri-implantitis is reported to account for 10% of the failures. As the oral cavity provides a natural habitat for various micro-organism due to its non-shedding surface, there is some evidence that gram-n...
متن کاملIn vitro microbiological analysis of bacterial seal at the implant-abutment interface using two morse taper implant models.
The objective of this study was to evaluate the bacterial seal at the implant-abutment interface using two morse taper implant models, by means of an in vitro microbiological analysis. For that were used 15 implants with mini-abutments tightened by friction, no screws (Group 1); and 30 implants with screw-tightened abutments, of which 15 received 20 N.cm of closing torque (Group 2) and the othe...
متن کاملLeakage of Microbial Endotoxin through the Implant-Abutment Interface in Oral Implants: An In Vitro Study
Background. Endotoxin initiates osteoclastic activity resulting in bone loss. Endotoxin leakage through implant abutment connections negatively influences peri-implant bone levels. Objectives. (i) To determine if endotoxin can traverse different implant-abutment connection (IAC) designs; (ii) to quantify the amount of endotoxins traversing the IAC; (iii) to compare the in vitro comportments of ...
متن کاملComparative evaluation of peri-implant tissues in patients wearing mandibular overdenture with different implant platforms
Background The poor hygiene of peri-implant tissues causes inflammation at tissue-implant interface, which may impair the rehabilitation success. The aim of this study was to evaluate the influence of external hexagon and Morse taper implants on peri-implant health in patients wearing mandibular overdentures for 1 year. Materials and Methods A total of 46 implants were evaluated, 28 external ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical oral implants research
دوره 21 3 شماره
صفحات -
تاریخ انتشار 2010