Prevention of encrustation and blockage of urinary catheters by Proteus mirabilis via pH-triggered release of bacteriophage

نویسندگان

  • Scarlet Milo
  • Hollie Hathaway
  • Jonathan Nzakizwanayo
  • Diana R. Alves
  • Patricia Pérez Esteban
  • Brian V. Jones
  • Toby A. Jenkins
چکیده

The crystalline biofilms of Proteus mirabilis can seriously complicate the care of patients undergoing long-term indwelling urinary catheterisation. Expression of bacterial urease causes a significant increase in urinary pH, leading to the supersaturation and precipitation of struvite and apatite crystals. These crystals become lodged within the biofilm, resulting in the blockage of urine flow through the catheter. Here, we describe an infection-responsive surface coating for urinary catheters, which releases a therapeutic dose of bacteriophage in response to elevated urinary pH, in order to delay catheter blockage. The coating employs a dual-layered system comprising of a lower hydrogel ‘reservoir’ layer impregnated with bacteriophage, capped by a ‘trigger’ layer of the pH-responsive polymer poly(methyl methacrylateco-methacrylic acid) (EUDRAGITS 100). Evaluation of prototype coatings using a clinically reflective in vitro bladder model system showed that catheter blockage time was doubled (13 h to 26 h (P o 0.05)) under conditions of established infection (10 CFU ml ) in response to a ‘burst-release’ of bacteriophage (10 PFU ml ). Coatings were stable both in the absence of infection, and in the presence of ureasenegative bacteria. Quantitative and visual analysis of crystalline biofilm reduction show that bacteriophage constitute a promising strategy for the prevention of catheter blockage, a clinical problem for which there is currently no effective control method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bacteriophage Can Prevent Encrustation and Blockage of Urinary Catheters by Proteus mirabilis.

Proteus mirabilis forms dense crystalline biofilms on catheter surfaces that occlude urine flow, leading to serious clinical complications in long-term catheterized patients, but there are presently no truly effective approaches to control catheter blockage by this organism. This study evaluated the potential for bacteriophage therapy to control P. mirabilis infection and prevent catheter block...

متن کامل

A sensor to detect the early stages in the development of crystalline Proteus mirabilis biofilm on indwelling bladder catheters.

A simple sensor has been developed to detect the early stages of urinary catheter encrustation and avoid the clinical crises induced by catheter blockage. In laboratory models of colonization by Proteus mirabilis, the sensor signaled encrustation at an average time of 43 h before catheters were blocked with crystalline biofilm.

متن کامل

Development of an antimicrobial urinary catheter to inhibit urinary catheter encrustation

Background: Encrustation of urinary catheters is a frequent problem in patients with long-term indwelling catheters colonised with urease-positive bacteria such as Proteus mirabilis. Catheter blockage may follow catheter encrustation, potentially leading to systemic infection. Prevention of encrustation is difficult and avoidance of recurrence often unsuccessful. One possible preventative strat...

متن کامل

Effect of triclosan on the formation of crystalline biofilms by mixed communities of urinary tract pathogens on urinary catheters.

The crystalline bacterial biofilms that encrust Foley catheters compromise the care of many elderly and disabled patients. The aim of this study was to examine whether the biocide triclosan can prevent encrustation by the mixed flora of uropathogens that commonly infect patients undergoing long-term catheterization. Models of the catheterized bladder were inoculated with communities of organism...

متن کامل

Control of encrustation and blockage of Foley catheters.

Urinary catheters often become encrusted and blocked by crystalline Proteus mirabilis biofilms. Results of experiments in a laboratory model of a Foley catheterised bladder infected with P mirabilis showed that when retention balloons were inflated with a solution of triclosan (10 g/L), the catheters drained freely for at least 7 days. Triclosan became impregnated throughout the silicone cathet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017