Refractive Correction and Biomechanical Strength Following SMILE With a 110- or 160-μm Cap Thickness, Evaluated Ex Vivo by Inflation Test.

نویسندگان

  • Iben Bach Damgaard
  • Anders Ivarsen
  • Jesper Hjortdal
چکیده

Purpose To examine the refractive correction and corneal biomechanical strength after small incision lenticule extraction (SMILE) by using a 110- or 160-μm cap thickness. Methods Thirty-two human donor corneas were allocated into 4 groups, combining one of two cap thicknesses (110 and 160 μm) with one of two spherical corrections (-4 D and -8 D). Each cornea was mounted on an artificial anterior chamber. The chamber pressure was adjusted by an attached 8% dextran media column. The anterior and posterior sagittal 3-mm-diameter curvature (rsag3mm) and the total corneal refractive power (TCRP4mm,apex,zone) were obtained before and after SMILE at a chamber pressure of 15 or 40 mm Hg. The average changes after surgery (Δ = postoperative - preoperative) and at increased chamber pressure (δ = 40 mm Hg - 15 mm Hg) were compared. Results A 110-μm cap thickness caused more anterior flattening (Δr15,-8D, 1.02 ± 0.08 mm versus 0.60 ± 0.17 mm), less posterior steepening (Δr15,-8D, -0.19 ± 0.11 mm versus -0.45 ± 0.20 mm), and more myopic correction (ΔTCRP15,-8D, -6.30 ± 0.96 D versus -4.55 ± 1.66 D) than a 160-μm cap thickness for -8 D SMILE (P < 0.034), but not for -4 D SMILE (ΔTCRP15,-4D,110μm, -3.86 ± 1.31 D versus ΔTCRP15,-4D,160μm, -3.57 ± 1.27 D, P = 0.718). After SMILE, increased chamber pressure caused anterior steepening (P < 0.014), which was similar at cap thicknesses of 110 and 160 μm (δr-4D, -0.13 ± 0.14 mm versus -0.09 ± 0.05mm, P = 0.431). Conclusions For high myopic corrections, a 160-μm cap caused less anterior curvature flattening and more posterior steepening than a 110-μm cap, and consequently less myopic correction. The inflation test revealed a reduction in the biomechanical strength after SMILE; this was similar when using a 110- or 160-μm cap thickness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Differences Between Femtosecond Lenticule Extraction (FLEx) and Small Incision Lenticule Extraction (SmILE) Tested by 2D-Extensometry in Ex Vivo Porcine Eyes.

Purpose To evaluate the biomechanical stability of ex vivo porcine corneas after femtosecond lenticule extraction (FLEx) and small incision lenticule extraction (SmILE) refractive surgeries. Methods Forty-five porcine eyes were equally divided into three groups: Groups 1 and 2 were treated with FLEx and SmILE procedure, respectively. Group 3 served as control. A refractive correction of -14 d...

متن کامل

Mathematical model to compare the relative tensile strength of the cornea after PRK, LASIK, and small incision lenticule extraction.

PURPOSE To develop a mathematical model to estimate the relative differences in postoperative stromal tensile strength following photorefractive keratectomy (PRK), LASIK, and small incision lenticule extraction (SMILE). METHODS Using previously published data where in vitro corneal stromal tensile strength was determined as a function of depth, a mathematical model was built to calculate the ...

متن کامل

Comparison of Two Cap Thickness in Small Incision Lenticule Extraction: 100μm versus 160μm

PURPOSE To compare the changes of biomechanical properties, endothelial cell density (ECD), and posterior corneal elevation (PCE) after femtosecond small incision lenticule extractions (SMILEs) with 100μm versus 160μm cap thicknesses. METHODS A total of 12 rabbits were randomly assigned into two groups of 6 each. SMILE was performed at a depth of either 160μm (160-cap group) or 100μm (100-cap...

متن کامل

Accuracy and precision of cap thickness in small incision lenticule extraction

AIMS To report and compare the cap thickness predictability of small incision lenticule extraction (SMILE) and flap thickness of femtosecond laser-assisted in situ keratomileusis (femto-LASIK). SETTINGS AND DESIGN Beyoglu Eye Training and Research Hospital, Refractive Surgery Department, Istanbul, Turkey. Retrospective pilot study. MATERIALS AND METHODS Medical records of patients who had S...

متن کامل

Comparison of corneal biomechanics after myopic small-incision lenticule extraction compared to LASIK: an ex vivo study

Purpose To investigate ex vivo potentially different corneal biomechanical properties after small-incision lenticule extraction (SMILE) versus LASIK for myopic correction. Methods Thirty human donor corneas were subjected to either myopic SMILE or femtosecond laser-assisted LASIK. Donor corneas were assigned to six investigative groups: Group A, -3.00 D (diopters) SMILE; Group B, -8.00 D SMIL...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 59 5  شماره 

صفحات  -

تاریخ انتشار 2018