Accelerated partial breast irradiation using the strut-adjusted volume implant single-entry hybrid catheter in brachytherapy for breast cancer in the setting of breast augmentation.

نویسندگان

  • Elizabeth S Bloom
  • Steve Kirsner
  • Bryan E Mason
  • Chris L Nelson
  • Kelly K Hunt
  • Donald P Baumann
  • Kent A Gifford
چکیده

PURPOSE Accelerated partial breast irradiation (APBI) has gained popularity as an alternative to adjuvant whole breast irradiation; however, owing to limitations of delivery devices for brachytherapy, APBI has not been a suitable option for all the patients. This report evaluates APBI using the strut-adjusted volume implant (SAVI) single-entry catheter to deliver brachytherapy for breast cancer in the setting of an augmented breast. METHODS AND MATERIALS The patient previously had placed bilateral subpectoral saline implants; stereotactic core biopsy revealed estrogen receptor- and progesterone receptor-positive ductal carcinoma in situ of intermediate nuclear grade. The patient underwent needle-localized segmental mastectomy of her left breast; pathologic specimen revealed no residual malignancy. An SAVI 8-1 device was placed within the segmental resection cavity. Treatment consisted of 3.4 Gy delivered twice a day for 5 days for a total dose of 34 Gy. Treatments were delivered with a high-dose-rate (192)Ir remote afterloader. RESULTS Conformance of the device to the lumpectomy cavity was excellent at 99.2%. Dosimetric values of percentage of the planning target volume for evaluation receiving 90% of the prescribed dose, percentage of the planning target volume for evaluation receiving 95% of the prescribed dose, volume receiving 150% of the prescribed dose, and volume receiving 200% of the prescribed dose were 97.1%, 94.6%, 22.7 cc, and 11.6 cc, respectively. Maximum skin dose was 115% of the prescribed dose. The patient tolerated treatment well with excellent cosmetic results, and limited acute and late toxicity at 8 weeks and 6 months, respectively. CONCLUSIONS Breast augmentation should not be an exclusion criterion for the option of APBI. The SAVI single-entry catheter is another option to successfully complete APBI using brachytherapy for breast cancer in the setting of an augmented breast.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A study on dosimetry accuracy of Strut-Adjust Volume Implant (SAVI) brachytherapy

Introduction: Accelerated Partial Breast Irradiation (APBI) is an effective treatment for breast carcinomas because of its limited number of fractions. Strut-adjusted volume implant (SAVI) is a HDR brachytherapy applicator to deliver the prescription dose with good PTV coverage and acceptable dose to skin, chest wall and organ at risks. Acceptable clinical outcomes depend on a...

متن کامل

Dosimetric performance of Strut-Adjusted Volume Implant: a new single-entry multicatheter breast brachytherapy applicator.

PURPOSE To evaluate the dosimetric performance and clinical utility of the Strut-Adjusted Volume Implant (SAVI) (Cianna Medical, Aliso Viejo, CA) applicator when used as the sole method of radiation therapy for patients with early breast carcinoma. METHODS AND MATERIALS The dosimetric performance of a Phase II clinical trial has been reported using the SAVI applicator for patients with early ...

متن کامل

Dosimetrical Evaluation and Clinical Implementation of a Strut-adjusted-volume-implant Savi Device Used for Accelerated Partial Breast Irradiation

The SAVI (the Strut Adjusted Volume Implant) device is one of the most novel devices used in Accelerated Partial Breast Irradiation (APBI). Various dosimetric parameters, as well as doses to adjacent critical structures, have been evaluated in 121 patients in this single institution 5-year retrospective study, using dose volume histogram (DVHs): Coverage Index (CI), cavity and planning target v...

متن کامل

Dosimetric considerations and early clinical experience of accelerated partial breast irradiation using multi-lumen applicators in the setting of breast augmentation

PURPOSE Accelerated partial breast irradiation (APBI) is an accepted treatment option in breast-conserving therapy for early stage breast cancer. However, data regarding outcomes of patients treated with multi-lumen catheter systems who have existing breast implants is limited. The purpose of this study was to report treatment parameters, outcomes, and possible dosimetric correlation with cosme...

متن کامل

Accelerated partial breast irradiation dosimetric criteria for the strut-adjusted volume implant.

PURPOSE Current guidelines for high-dose-rate accelerated partial breast irradiation using single-entry implants are based on the National Surgical Adjuvant Breast and Bowel Project B-39/Radiation Therapy Oncology Group 0413 protocol, which assumed a balloon implant geometry. We have developed robust plan evaluation criteria specifically for the strut-adjusted volume implant (SAVI). METHODS A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brachytherapy

دوره 10 3  شماره 

صفحات  -

تاریخ انتشار 2011