Therapeutic indices for transchest defibrillator shocks: effective, damaging, and lethal electrical doses.

نویسندگان

  • C F Babbs
  • W A Tacker
  • J F VanVleet
  • J D Bourland
  • L A Geddes
چکیده

Although prospective studies of defibrillator shock overdose cannot be performed in man, the therapeutic indices of various defibrillating current waveforms can be measured in animals. We determined the ratios TD50/ED50 and LD50/ED50 (where TD50 = median "toxic" or damage-inducing dose, ED50 = median effective or defibrillating dose, and LD50 = median lethal dose) as measures of the therapeutic index for damped sine wave defibrillator shocks in dogs. Death of an animal and/or any degree of cardiac damage found by gross or microscopic examination were defined as harmful effects of shock, analogous to drug toxicity. In terms of peak current, the ED50, TD50, and LD50 were 1.1, 5.8, and 24 amperes/kg.; the therapeutic indices were TD50/ED50 = 5 for morphologic damage and LD50/ED50 = 22 for death. In terms of delivered energy the ED50, TD50, and LD50 were 1.5, 30, and 470 joules/kg.; the therapeutic indices were TD50/ED50 = 20 for damage and LD50/ED50 = 320 for death. These data indicate a reasonable margin of safety for damped sine wave defibrillator shocks in dogs, and are consistent with reported incidences of suspected shock-induced damage in humans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The evaluation and management of electrical storm.

Electrical storm is an increasingly common and life-threatening syndrome that is defined by 3 or more sustained episodes of ventricular tachycardia, ventricular fibrillation, or appropriate shocks from an implantable cardioverter-defibrillator within 24 hours. The clinical presentation can be dramatic. Electrical storm can manifest itself during acute myocardial infarction and in patients who h...

متن کامل

A better method for preventing adverse clinical events caused by implantable cardioverter-defibrillator lead fractures?

In October 2007, the Medtronic Sprint Fidelis implantable cardioverter-defibrillator (ICD) lead was voluntarily withdrawn from the market by the manufacturer because of a higher-than-expected fracture rate.1 Most Sprint Fidelis fractures involve the pace-sense component of the lead, which may cause oversensing of electrical artifacts, undersensing of ventricular depolarizations, and/or loss of ...

متن کامل

Psychological indices as predictors for phantom shocks in implantable cardioverter defibrillator recipients.

BACKGROUND A phantom shock-the sensation of an implantable cardioverter defibrillator (ICD) discharge in the absence of an actual discharge-is a phenomenon that can occur in ICD patients. Little is known about the influence of psychological factors on the incidence of phantom shocks. We evaluated psychological correlates of phantom shocks 2 years post-ICD implant in a cohort of Dutch ICD recipi...

متن کامل

A Basic Mechanism of Defibrillation Failure

Delivery of a strong electric shock to the heart remains the only effective therapy against ventricular fibrillation. Despite significant improvements in implantable cardioverter defibrillator (ICD) therapy, the fundamental mechanisms of defibrillation remain poorly understood. We have recently demonstrated that a monophasic defibrillation shock produces a highly nonuniform epicardial polarizat...

متن کامل

Impaired cardiac sympathetic innervation and myocardial perfusion are related to lethal arrhythmia: quantification of cardiac tracers in patients with ICDs.

UNLABELLED Despite widespread prophylactic use of implantable cardioverter defibrillator (ICD) therapy, sudden cardiac death and refractory arrhythmia events are still important clinical issues to be overcome. We examined whether the impairment of cardiac sympathetic innervation and myocardial perfusion is responsible for lethal arrhythmic events and has prognostic value by comparing convention...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American heart journal

دوره 99 6  شماره 

صفحات  -

تاریخ انتشار 1980