Stainless steel wire versus FiberWire suture cerclage fixation to stabilize the humerus in total shoulder arthroplasty.

نویسندگان

  • Niklas Renner
  • Karl Wieser
  • Georg Lajtai
  • Mark E Morrey
  • Dominik C Meyer
چکیده

HYPOTHESIS No. 5 FiberWire (Arthrex, Naples, FL, USA) cerclage (FWC) and 1.25-mm stainless steel wire cerclage (SSWC) are biomechanically similar in resistance to prosthetic subsidence in shoulder arthroplasty. METHODS In this laboratory bench study, 3 different surgical knot configurations (4-throw knot, cow hitch, and simple hitch) using a No. 5 FWC were evaluated and compared with a 1.25-mm SSWC. First, distraction tests were performed using bovine femoral cortical half shells mounted on a testing jig. Cerclage tightening, load to a 3-mm gap opening, and load to total failure were measured. Second, uncemented humeral prosthetic stems were inserted into an experimentally split humeral medullary canal, secured by the cerclage. After 100 N of preloading, the prosthesis was advanced into the humerus at a speed of 0.2 mm/s, and resistance during subsidence up to a penetration depth of 10 mm, as well as gap opening, was measured. RESULTS Tightening force showed higher values for SSWC (618 N) than FWC (131-137 N) (P < .001). Load to total failure was comparable among the 3 different FWC knots (2,642-2,804 N), which were significantly stronger than SSWC (1,775 N, P < .001). At 3 mm of distraction, SSWC (1,820 N), cow hitch (1,803 N), and single-throw hitch (1,709 N) performed significantly better than a 4-throw knot (1,289 N) (P < .01). Subsidence testing showed no difference in force restraint or gap opening between the best FWC and SSWC. CONCLUSIONS FWCs appear, in vitro, equally suitable to steel wires to stabilize nondisplaced periprosthetic humeral fractures. To actively reduce a displaced fracture, steel wires may still be the first choice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prophylactic Cerclage With Braided Polyblend Suture During Femoral Broaching.

Femur fractures occur during broaching and impaction of the implant during hip arthroplasty. Prophylactic cerclage of the proximal femur with braided cable and steel wire has been shown to decrease hoop stresses and has been posited as a way to decrease the incidence of intraoperative fracture. In this biomechanical study, the authors investigated the strain across the proximal femur during bro...

متن کامل

Medial malleolar fractures: a biomechanical study of fixation techniques.

Fracture fixation of the medial malleolus in rotationally unstable ankle fractures typically results in healing with current fixation methods. However, when failure occurs, pullout of the screws from tension, compression, and rotational forces is predictable. We sought to biomechanically test a relatively new technique of bicortical screw fixation for medial malleoli fractures. Also, the AO gro...

متن کامل

Short Stem Reverse Total Shoulder Arthroplasty Periprosthetic Type A Fracture.

Alterations have been made over the years to the standard reverse total shoulder arthroplasty (RTSA) prosthetic components in an effort to decrease adverse events; this has led to the advent of a short humeral stem prosthesis. To the authors' knowledge, there are no reports describing the complication of a traumatic periprosthetic Wright and Cofield classification type A fracture with use of a ...

متن کامل

Fixation of the greater tuberosity in proximal humeral fractures: FiberWire® or wire cerclage?

Proximal humeral fractures remain a surgical challenge, and scientific discussions are commonly focused on their ideal treatment. One possible treatment involves the use of an angle stable plate osteosynthesis. However, which material can most feasibly be used to attach the greater tuberosity to the implant remains unknown. In two prospective, non-randomized trials, we compared the results of a...

متن کامل

The use of three types of suture and stainless steel wire tension banding for the fixation of simulated olecranon fractures: a comparison study in cadaver elbows.

Using an osteotomy of the olecranon as a model of a transverse fracture in 22 cadaver elbows we determined the ability of three different types of suture and stainless steel wire to maintain reduction when using a tension-band technique to stabilise the bone. Physiological cyclical loading simulating passive elbow movement (15 N) and using the arms to push up from a chair (450 N) were applied u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of shoulder and elbow surgery

دوره 23 10  شماره 

صفحات  -

تاریخ انتشار 2014