Optimized 3 T EPI of the amygdalae.

نویسندگان

  • S Robinson
  • C Windischberger
  • A Rauscher
  • E Moser
چکیده

The optimum parameters for single-shot gradient-recalled (GR) EPI-based fMRI studies of the limbic region are systematically established at 3 T via their ability to mitigate intravoxel dephasing-measured via SNR and T2* in the amygdalae-and their implications for temporal resolution (or brain coverage). Conventional imaging parameters (64 x 64 matrix size and 4-6 mm thick slices) are confirmed to be inadequate for functional studies at 3 T. Measurements of main magnetic field variations across the amygdalae suggest that such variations are equal in the craniocaudal and anterior-posterior directions, and slightly lower in the mediolateral direction, with this and other considerations leading us to conclude an oblique axial orientation to be most suitable. In-plane resolution of approximately 1.7 mm was sufficient to recover signal in the area of the amygdalae. SNR was found to peak at a slice thickness of between 2.0 and 2.5 mm, dependent on the subject. T2* time in the amygdalae was measured with a standard EPI protocol to be 22 +/- 3 ms. Using the optimized (high resolution) EPI protocol proposed here, the measured T2* time increased to 48 +/- 2 ms (compared with 43 +/- 3 ms for a reference FLASH scan), only slightly lower than the cortex (49 +/- 2 ms measured with optimized EPI and 52 +/- 2 ms with FLASH). The FLASH measurement of 43 ms is taken to be a suitable effective echo time (TE(eff)) to achieve maximum BOLD sensitivity in the amygdalae. Time series data acquired with these parameters showed a 60% increase in SNR in the amygdala over that obtained with a standard low-resolution protocol and suggest sufficient SNR and BOLD sensitivity to make functional studies feasible. Arteries, but no substantial draining veins, were found in high-resolution BOLD venograms of the region. Our results indicate that EPI protocols need to be carefully optimized for structures of interest if reliable results from single subjects are to be established in this brain region.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Event-related Whole-brain Fmri: Epi with Slice Dependent Echo times versus Standard Epi

Table 1. Nstd/mod is the sum of supra-threshold voxels (p<0.001 unc., clustersize 5) for different ROIs (see legend below) found in the standard and the modified EPI datasets for the contrasts rewardpunishment, reward-baseline and punishment-baseline. Zstd/mod specifies the maximal Z-score. ROI 1: Insula, ROI 2: Amygdalae, ROI 3: Putamen, ROI 4: Thalamus, ROI 5: Caudate, ROI 6: Parahippocampal ...

متن کامل

High-Resolution Functional MRI at 3 T: 3D/2D Echo-Planar Imaging with Optimized Physiological Noise Correction

High-resolution functional MRI (fMRI) offers unique possibilities for studying human functional neuroanatomy. Although high-resolution fMRI has proven its potential at 7 T, most fMRI studies are still performed at rather low spatial resolution at 3 T. We optimized and compared single-shot two-dimensional echo-planar imaging (EPI) and multishot three-dimensional EPI high-resolution fMRI protocol...

متن کامل

Fast high-resolution T1 mapping using inversion-recovery Look-Locker echo-planar imaging at steady state: optimization for accuracy and reliability.

A fast T(1) measurement sequence using inversion recovery Look-Locker echo-planar imaging at steady state (IR LL-EPI SS) is presented. Delay time for a full magnetization recovery is not required in the sequence, saving acquisition time significantly for high-resolution T(1) mapping. Imaging parameters of the IR LL-EPI SS sequence were optimized to minimize the bias from the excitation pulses i...

متن کامل

Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3 T using interleaved echo planar imaging.

OBJECTIVES The goal of this work was to reduce the scan time of contrast-enhanced whole-heart coronary magnetic resonance angiography (MRA) by using a gradient echo interleaved echo planar imaging (GRE-EPI) sequence at 3 T field strength. MATERIALS AND METHODS A GRE-EPI sequence was optimized to acquire contrast-enhanced whole-heart coronary MRA at 3 T. First-order phase correction was used f...

متن کامل

Optimized perioperative analgesia reduces chronic phantom limb pain intensity, prevalence, and frequency: a prospective, randomized, clinical trial.

BACKGROUND Severe preamputation pain is associated with phantom limb pain (PLP) development in limb amputees. We investigated whether optimized perioperative analgesia reduces PLP at 6-month follow-up. METHODS A total of 65 patients underwent lower-limb amputation and were assigned to five analgesic regimens: (1) Epi/Epi/Epi patients received perioperative epidural analgesia and epidural anes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 22 1  شماره 

صفحات  -

تاریخ انتشار 2004