Use of multiple colorimetric indicators for paper-based microfluidic devices.

نویسندگان

  • Wijitar Dungchai
  • Orawon Chailapakul
  • Charles S Henry
چکیده

We report here the use of multiple indicators for a single analyte for paper-based microfluidic devices (microPAD) in an effort to improve the ability to visually discriminate between analyte concentrations. In existing microPADs, a single dye system is used for the measurement of a single analyte. In our approach, devices are designed to simultaneously quantify analytes using multiple indicators for each analyte improving the accuracy of the assay. The use of multiple indicators for a single analyte allows for different indicator colors to be generated at different analyte concentration ranges as well as increasing the ability to better visually discriminate colors. The principle of our devices is based on the oxidation of indicators by hydrogen peroxide produced by oxidase enzymes specific for each analyte. Each indicator reacts at different peroxide concentrations and therefore analyte concentrations, giving an extended range of operation. To demonstrate the utility of our approach, the mixture of 4-aminoantipyrine and 3,5-dichloro-2-hydroxy-benzenesulfonic acid, o-dianisidine dihydrochloride, potassium iodide, acid black, and acid yellow were chosen as the indicators for simultaneous semi-quantitative measurement of glucose, lactate, and uric acid on a microPAD. Our approach was successfully applied to quantify glucose (0.5-20 mM), lactate (1-25 mM), and uric acid (0.1-7 mM) in clinically relevant ranges. The determination of glucose, lactate, and uric acid in control serum and urine samples was also performed to demonstrate the applicability of this device for biological sample analysis. Finally results for the multi-indicator and single indicator system were compared using untrained readers to demonstrate the improvements in accuracy achieved with the new system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thread as a matrix for biomedical assays.

This paper describes the use of thread as a matrix for the fabrication of diagnostic assay systems. The kinds of thread used for this study are inexpensive, broadly available, and lightweight; some of them are already familiar materials in healthcare. Fluids wick along these threads by capillary action; no external power source is necessary for pumping. This paper demonstrates three designs for...

متن کامل

Tree-shaped paper strip for semiquantitative colorimetric detection of protein with self-calibration.

This paper described a convenient semiquantitative method for colorimetric detection of protein with self-calibration integrated on the test strip. Hydrophilic paper was employed as microfluidic device for running colorimetric assay, tree-shaped design was developed to ensure uniform microfluidic flow for multiple branches. The approach was validated with bovine serum albumin (BSA) colorimetric...

متن کامل

Microfluidic devices constructed by a marker pen on a silica gel plate for multiplex assays.

In this report, we describe a simple-to-fabricate microfluidic device constructed on a silica gel plate by a waterproof marker pen. We call it pen-based assay on silica, which was successfully applied to simultaneously analyze multiple targets qualitatively and quantitatively based on colorimetric assays for protein, glucose, and pH value.

متن کامل

Simple telemedicine for developing regions: camera phones and paper-based microfluidic devices for real-time, off-site diagnosis.

This article describes a prototype system for quantifying bioassays and for exchanging the results of the assays digitally with physicians located off-site. The system uses paper-based microfluidic devices for running multiple assays simultaneously, camera phones or portable scanners for digitizing the intensity of color associated with each colorimetric assay, and established communications in...

متن کامل

Flexible microfluidic cloth-based analytical devices using a low-cost wax patterning technique.

This paper describes the fabrication of microfluidic cloth-based analytical devices (μCADs) using a simple wax patterning method on cotton cloth for performing colorimetric bioassays. Commercial cotton cloth fabric is proposed as a new inexpensive, lightweight, and flexible platform for fabricating two- (2D) and three-dimensional (3D) microfluidic systems. We demonstrated that the wicking prope...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytica chimica acta

دوره 674 2  شماره 

صفحات  -

تاریخ انتشار 2010