Causes of failure of ceramic-on-ceramic and metal-on-metal hip arthroplasties.
نویسندگان
چکیده
BACKGROUND Few large series of hard bearing surfaces have reported on reasons for early failure. A number of unique mechanisms of failure, including fracture, squeaking, and adverse tissue reactions, have been reported with these hard bearing surfaces. However, the incidence varies among the published studies. QUESTIONS/PURPOSES To confirm the incidences, we identified the etiologies of early failures of hard-on-hard bearing surfaces for ceramic-on-ceramic and metal-on-metal THAs. METHODS We retrospectively reviewed records of 2907 THAs with hard-on-hard bearing surfaces implanted between 1996 and 2009; 1697 (58%) had ceramic-on-ceramic and 1210 (42%) had metal-on-metal bearing surfaces. We recorded bearing-related complications and compared them to nonspecific reasons for revision THA. The minimum followup of the ceramic-on-ceramic and metal-on-metal cohorts was 6 months (mean, 48 months; range, 6-97 months) and 24 months (mean, 60 months; range, 24-178 months), respectively. RESULTS The overall revision rate for ceramic-on-ceramic THA was 2.2% (38 of 1697), with aseptic loosening accounting for 55% of revisions (femur or acetabulum). The bearing accounted for 13% of the revisions in the ceramic-on-ceramic THA cohort. The overall metal-on-metal revision rate was 5.4% (65 of 1210), 17 involving adverse tissue reactions related to the metal-on-metal bearing surface (17 of 1210, 1.4% of cases; 17 of 65, 26% of revisions). CONCLUSIONS Twenty-six percent of the revisions from metal-on-metal and 13% of ceramic-on ceramic were bearing related. The overall short- to medium-term revision rate was 2.2% and 5.4% for ceramic-on-ceramic and metal-on-metal, respectively. The most common etiology of failure was loosening of the femoral or acetabular components. LEVEL OF EVIDENCE Level IV, therapeutic study. See the Guidelines for Authors for a complete description of level of evidence.
منابع مشابه
Cobalt toxicity after revision to a metal-on-polyethylene total hip arthroplasty for fracture of ceramic acetabular component
Cobalt metallosis after revision metal-on-polyethylene total hip arthroplasty for catastrophic failure of ceramic components is uncommon but a potentially devastating complication. Common findings associated with heavy metal toxicity include cardiomyopathy, hypothyroidism, skin rashes, visual disturbances, hearing changes, polycythemia, weakness, fatigue, cognitive deterioration, and neuropathy...
متن کاملFatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature
Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...
متن کاملThe evaluation and comparison of marginal adaptation in metal ceramic and all ceramic restorations fabricated by two methods: CAD/CAM and conventional
Introduction: Marginal fit is a key factor for long term clinical success through any dental restorations. Poor marginal adaptation causes cement dissolution. This can lead to dental caries, gingival irritation, periodontal diseases, and finally treatment failure. The aim of this study was measurement and comparison of marginal gap quantities in metal ceramic and all ceramic dental restorations...
متن کاملFatal Cobalt Toxicity after a Non-Metal-on-Metal Total Hip Arthroplasty
This case illustrates the potential for systemic cobalt toxicity in non-metal-on-metal bearings and its potentially devastating consequences. We present a 71-year-old male with grinding sensations in his right hip following ceramic-on-ceramic total hip arthroplasty (THA). After diagnosing a fractured ceramic liner, the hip prosthesis was revised into a metal-on-polyethylene bearing. At one year...
متن کاملAlumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study.
BACKGROUND Ceramic-on-ceramic couplings are attractive alternative bearing surfaces that have been reported to eliminate or reduce problems related to polyethylene wear debris. Disappointing experiences with alumina ceramic bearings in the past have led to many improvements in the manufacture and design of ceramic implants. The purpose of the present study was to report the results of contempor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical orthopaedics and related research
دوره 470 2 شماره
صفحات -
تاریخ انتشار 2012