Effects of stent sizing on endothelial and vessel wall stress: potential mechanisms for in-stent restenosis.
نویسندگان
چکیده
Stent sizing and apposition have been shown to be important determinants of clinical outcome. This study evaluates the mechanical effects of undersizing and oversizing of stents on endothelial wall shear stress (WSS) and vessel wall stress to determine a possible biomechanical mechanism of in-stent restenosis and thrombosis. Three-dimensional computational models of stents, artery, and internal fluid were created in a computer-assisted design package, meshed, and solved in finite element and computational fluid dynamic packages. The simulation results show that the effects of various degrees of undersizing on WSS, WSS gradient, and oscillatory shear index were highly nonlinear. As the degree of undersizing increased, the heterogeneity of WSS became smaller. The WSS distribution for the 20% undersizing was smooth and uniform, whereas the 5% case was very heterogeneous. The combination of lower WSS and higher WSS gradient and oscillatory shear index in the 5% undersized case may induce neointimal hyperplasia or thrombosis. Additionally, the oversizing simulation results show that the maximum intramural wall stress of the 20% oversizing case is significantly larger than the maximum stress for the 10% and zero oversizing cases. Edge stress concentration was observed, consistent with the restenosis typically observed in this region. This study demonstrates that proper sizing of stent is important for reducing the hemodynamic and mechanical disturbances to the vessel wall. Furthermore, the present findings may be used to improve stent design to reduce endothelial flow disturbances and intramural wall stress concentrations.
منابع مشابه
TRANSLATIONAL PHYSIOLOGY Effects of stent sizing on endothelial and vessel wall stress: potential mechanisms for in-stent restenosis
Henry Y. Chen, James Hermiller, Anjan K. Sinha, Michael Sturek, Luoding Zhu, and Ghassan S. Kassab Weldon School of Biomedical Engineering, Purdue University, West Lafayette; Department of Cardiovascular Surgery, St. Vincent Hospital, Indianapolis; and Departments of Medicine (Cardiology), Mathematical Sciences, Surgery, Cellular and Integrative Physiology, and Biomedical Engineering, Indiana U...
متن کاملOverview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent
Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...
متن کاملFabrication of Spiral Stent with Superelastic/ Shape Memory Nitinol Alloy for Femoral Vessel
Stent is a metal mesh tube for opening the obstructed vessels of the body. Ni-Ti alloy is a suitable metal for fabrication of stent due to its potential for applying the appropriate stress and strain to the vessel walls. In this study, super-elastic Nitinol wire was used to build stent samples usable to open femoral vessel. Ageing was performed at 500°C for different periods of time to determin...
متن کاملImpact of stent mis-sizing and mis-positioning on coronary fluid wall shear and intramural stress.
Stent deployments with geographical miss (GM) are associated with increased risk of target-vessel revascularization and periprocedural myocardial infarction. The aim of the current study was to investigate the underlying biomechanical mechanisms for adverse events with GM. The hypothesis is that stent deployment with GM [longitudinal GM, or LGM (i.e., stent not centered on the lesion); or radia...
متن کاملImpact of main branch stenting on endothelial shear stress: role of side branch diameter, angle and lesion.
In-stent restenosis and stent thrombosis remain clinically significant problems for bifurcation lesions. The objective of this study is to determine the haemodynamic effect of the side branch (SB) on main branch (MB) stenting. We hypothesize that the presence of a SB has a negative effect on MB wall shear stress (WSS), wall shear stress gradient (WSSG) and oscillatory shear index (OSI); and tha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 106 5 شماره
صفحات -
تاریخ انتشار 2009