Monte Carlo study of photoneutron production in U-235 following perturbations in cross section data
نویسندگان
چکیده
Article history: Received 8 October 2008 Received in revised form 19 November 2008 Accepted 19 November 2008 Available online 12 January 2009 0306-4549/$ see front matter 2008 Elsevier Ltd. A doi:10.1016/j.anucene.2008.11.023 * Corresponding author. Tel.: +1 734 615 7830; fax E-mail address: [email protected] (S.D. Clarke). Active photon interrogation systems may be employed to detect high-Z isotopes without significant spontaneous fission emissions. These systems induce photonuclear reactions with emissions (such as fission neutrons) that may be detected. However, there are inconsistencies in the literature reporting resonance photonuclear interaction data for many isotopes. Recent publications show variations as large as 20% between various measurements of photonuclear cross section data. A perturbation methodology utilizing the modular nature of the MCNPX/MCNP-PoliMi code system has been implemented and is applied here to highly-enriched uranium. Monoenergetic photon sources between 8 and 18 MeV were simulated; neutron detection was performed using the MCNP-PoliMi liquid scintillator model. At photon energies less than 12 MeV, the number of detected neutrons is approximately 70% sensitive to changes in the (c, f) cross section and 30% sensitive to changes in the (c,n) cross section. As gamma-ray energy increases the (c, f) sensitivity increases and the (c,n) sensitivity decreases. There is a small (c,2n) sensitivity at photon energies between 15 and 17 MeV. The ability of modern simulation tools to predict photonuclear responses is greatly limited in this energy region due to the high sensitivity of the simulated results to observed discrepancies in photonuclear cross section data. 2008 Elsevier Ltd. All rights reserved.
منابع مشابه
Sensitivity of Photoneutron Production to Perturbations in Cross-Section Data
The most recent release of photonuclear interaction data for Monte Carlo applications is the ENDF/B-VII library. While this current version offers several improvements over its predecessors, it does not address the observed, sometimes quite significant variance in the measured data. For instance, for U, the cross-section data in the ENDF/B-VII library is consistently larger than all measurement...
متن کاملDesign and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy
Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...
متن کاملDesign and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy
Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...
متن کاملA Monte Carlo Study for Photoneutron Dose Estimations around the High-Energy Linacs
Background: High-energy linear accelerator (linac) is a valuable tool and the most commonly device for external beam radiation treatments in cancer patients. In the linac head, high-energy photons with energies above the threshold of interaction produce photoneutrons. These photoneutrons deliver the extra dose to the patients in the planning treatment and increase the risk of secondary cancer.O...
متن کاملA N ABSOLUTE DETERMINATION OF THE ~35U FISSION CROSS SECTION AT 964 keV*
-An absolute measurement of the 235U fission cross section has been carried out using a S4Na-Be photoneutron source with median neutron energy of 964 keV. A symmetric two-foil experiment was set up to measure the fission rate in a low-albedo laboratory, and variations in the sourceto-foil spacing used to determine the room background. Fission fragments passing through a limited solid angle aper...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -