Clival Screw Placement in Patient with atlas assimilation: A CT-based feasibility study
نویسندگان
چکیده
Clival screw and plate fixation technique is an alternative or supplement to the occipitocervical instrumentation. However, no report has clarified the applied anatomy of clivus in patients with atlas assimilation (C1A), especially for clival screw fixation. Therefore, we measured the parameters of clival lengths, widths, putative screw lengths, clival-cervical angel and foramen magnum diameters on CT images in a cohort of 81 C1A patients and patients without C1A. The clivus showed a rectangular shape in 96.3% (78/81) of C1A patients, and a normal-like triangle shape in 3.7% (3/81) of C1A patients. The intracranial clival length decreased 13% (37 mm) in C1A patients, the extracranial clival length 14.8% (24.1 mm), the clival-cervical angle 6.2% (122.3°) and the superior screw length 11.3% (14.1 mm), the sagittal diameter of foramen magnum 16% (28.0 mm), respectively. There was no significant difference in the widest or narrowest clival width, or the middle screw length, or the transverse diameter of foramen magnum between groups. The inferior clivus was feasible for an average 9.7-mm-length screw placement in C1A patients, while not in patients without C1A. The present study characterizes clivus of C1A patients with an unnormal-like rectangular shape, and confirmes a screw placement at the inferior clivus.
منابع مشابه
CT-based morphometric analysis of C1 laminar dimensions: C1 translaminar screw fixation is a feasible technique for salvage of atlantoaxial fusions
BACKGROUND Translaminar screw fixation has become an alternative in the fixation of the axial and subaxial cervical spine. We report utilization of this approach in the atlas as a salvage technique for atlantoaxial stabilization when C1 lateral mass screws are precluded. To assess the feasibility of translaminar fixation at the atlas, we have characterized the dimensions of the C1 lamina in the...
متن کاملMorphometric Study of C1 Pedicle and Feasibility Evaluation of C1 Pedicle Screw Placement with a Novel Clinically Relevant Radiological Classification in an Indian Population
Study Design A retrospective computed tomography (CT)-based morphometric study of 84 C1pedicles in an Indian population focusing on critical morphometric dimensions vis-a-vis C1 pedicle screw placement. Purpose To determine the feasibility of C1 pedicle screw placement in an Indian population and propose a novel classification system for the same. Overview of Literature At present, C1 pedic...
متن کاملThree-dimensional spiral CT measurement of atlantal pedicle and its clinical application
The study aimed to establish the safe placement area and corresponding entry angle of atlantal pedicle screw using axial computed tomography (CT) measurement of atlas, in order to guide the clinical operation. Spiral thin-slice CT scan of atlas and three-dimensional reconstruction of 38 patients were randomly selected. Screw placement space was defined as the distance between the tangent lines ...
متن کاملImage-based versus atlas-based patient-specific S-value assessment for Samarium-153 EDTMP cancer palliative care: A short study
Introduction: Use of SPECT/CT data is the most accurate method for patient-specific internal dosimetry when isotopes emit single gamma rays. The manual or semi-automatic segmentation of organs is a major obstacle that slows down and limits the patient-specific dosimetry. Using digital phantoms that mimic patient’s anatomy can bypass the segmentation step and facilitate the dosi...
متن کاملGenerating Synthetic Computed Tomography and Synthetic Magnetic Resonance (sMR: sT1w/sT2w) Images of the Brain Using Atlas-Based Method
Introduction: Nowadays, magnetic resonance imaging (MRI) in combination with computed-tomography (CT) is increasingly being used in radiation therapy planning. MR and CT images are applied to determine the target volume and calculate dose distribution, respectively. Since the use of these two imaging modalities causes registration uncertainty and increases department w...
متن کامل