Balloon catheter test in patients with atrial septal defect and patent ductus arteriosus.

نویسندگان

  • T Sakurai
  • H Hoshino
  • Y Suzuki
  • H Yokoi
  • K Sakanaka
  • K Enomoto
  • N Okada
چکیده

Since 1973, the balloon catheter test with a Swan-Ganz, Dotter-Lukas or Fogarty catheter has been attempted in our department in cases of atrial septal defect (ASD) and patent ductus arteriosus (PDA) during cardiac catheterization and operation. Accurate informations concerning size, number and location of ASD were obtained during cardiac catheterization studies by using the balloon catheter. The difference between the size of the defect measured at catheterization and at operation was less than 1 mm in diameter. Size of the defect ranged from 13 to 44 mm in diameter (25.7 mm on the average) and bacame larger with patient's age. Measurement of left-to-right shunt ratios before and after the temporary balloon occlusion of the defect was of help in making a preoperative diagnosis of ASD with multiple defects. Size of foramen ovale ranged from 3 to 13 mm in diameter (5.2 mm on the average) and was not related to age. Size of the ductus in cases with PDA was measured during cardiac catheterization by using the balloon catheter. The difference between the size of the ductus measured with the balloon technique at catheterization and with a measuring rule at operation was less than 4 mm in diameter. The difference revealed the extensibility of the ductus. The temporary balloon occlusion of the ductus aided in determining presence of other cardiac anomalies. In cases of isolated PDA, the murmur became inaudible with the occlusion of the ductus. A balloon catheter inflated with radiopaque dye was used for measurements at cardiac catheterization and at operation. Persistent arrhythmias or other adverse effects of this procedure were not observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Antegrade balloon valvuloplasty for critical aortic stenosis in a premature neonate weighing 1100 g.

Experiences with invasive cardiac catheterization in low birth weight infants are few. In our clinic, we performed balloon aortic valvuloplasty by antegrade approach in a neonate weighing 1100 g with critical aortic stenosis, patent ductus arteriosus and atrial septal defect. The right femoral vein was accessed with a 4 Fr sheath, and a catheter was placed into the left ventricle from the atria...

متن کامل

Catheter balloon valvuloplasty of aortic and mitral stenosis in adults : 1987

THERAPEUTIC catheter intervention probably started with Dotter and Judkins performance of transluminal treatment of arteriosclerotic obstruction of peripheral vessels.' Rashkind extended the therapeutic use of the catheter to intracardiac work with the performance of balloon atrial septostomy for transposition of the great arteries.2 Over the next 20 years, the field has blossomed, with removal...

متن کامل

Fate of infants with transposition of the great arteries in relation to balloon atrial septostomy.

The palliation afforded by balloon atrial septostomy to 124 infants with transposition of the great arteries was assessed in terms of survival to 6 months of age without the need for further intervention. Prediction of success or failure in relation to palliation was significantly affected by the presence of associated ventricular septal defect, left ventricular outflow tract obstruction, or pe...

متن کامل

Left Pulmonary Artery Sling Associated with Patent Ductus Arteriosus and Atrial Septal Defect: Evaluation with Multidetector CT

We report a case of left pulmonary artery sling associated with patent ductus arteriosus and atrial septal defect in a 21-month-old child. 256-slice MDCT provides valuable information, such as abnormal origin of the left pulmonary artery, the relationship between pulmonary artery and airway, the diameter of the patent ductus artery and atrial septal defect. The information is helpful in diagnos...

متن کامل

Double-umbrella closure of atrial defects. Initial clinical applications.

Forty patients were catheterized for closure of atrial septal defects with the Rashkind patent ductus arteriosus umbrella device, a modified Rashkind umbrella device, and the newly designed Lock Clamshell Occluder. Patients weighed 8 kg or more (a requirement for transvenous access with the 11F delivery sheath) and had defects suitable for closure based on two-dimensional echocardiography. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Japanese heart journal

دوره 21 6  شماره 

صفحات  -

تاریخ انتشار 1980