Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression

نویسندگان

  • Gil Herrnstadt
  • Carlo Menon
چکیده

Robotic technology is gradually becoming commonplace in the medical sector and in the service of patients. Medical conditions that have benefited from significant technological development include stroke, for which rehabilitation with robotic devices is administered, and surgery assisted by robots. Robotic devices have also been proposed for assistance of movement disorders. Pathological tremor, among the most common movement disorders, is one such example. In practice, the dissemination and availability of tremor suppression robotic systems has been limited. Devices in the marketplace tend to either be non-ambulatory or to target specific functions, such as eating and drinking. We have developed a one degree-of-freedom (DOF) elbow orthosis that could be worn by an individual with tremor. A speed-controlled, voluntary-driven suppression approach is implemented with the orthosis. Typically tremor suppression methods estimate the tremor component of the signal and produce a canceling counterpart signal. The suggested approach instead estimates the voluntary component of the motion. A controller then actuates the orthosis based on the voluntary signal, while simultaneously rejecting the tremorous motion. In this work, we tested the suppressive orthosis using a one DOF robotic system that simulates the human arm. The suggested suppression approach does not require a model of the human arm. Moreover, the human input along with the orthosis forearm gravitational forces, of non-linear nature, are considered as part of the disturbance to the suppression system. Therefore, the suppression system can be modeled linearly. Nevertheless, the orthosis forearm gravitational forces can be compensated by the suppression system. The electromechanical design of the orthosis is presented, and data from an essential tremor patient is used as the human input. Velocity tracking results demonstrate an RMS error of 0.31 rad/s, and a power spectral density shows a reduction of the tremor signal by 99.8%, while the intentional component power was reduced by <1%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Active Tremor Estimation and Suppression in Human Elbow Joint

A new control algorithm was developed for tremor estimation and suppression in a second order linear model of the human elbow joint. An adaptive method developed to estimate a simple harmonic disturbance was generalized for tremorous motion with spectral composition similar to the clinical reports for action tremor. Numerical simulations showed the ability of proposed controller to reduce tremo...

متن کامل

Design of a controlled-energy-dissipation orthosis (CEDO) for functional suppression of intention tremors.

Conventional neurological practice is generally not successful in restoring independent upper extremity function to people with disabiling tremors. The authors have been investigating an orthotic approach, the application of energy-dissipating loads to affected limbs, to allow voluntary intent to be expressed while attenuating tremor. CEDO 1 is a prototype Controlled-Energy-Dissipation Orthosis...

متن کامل

On-Off Tremor Suppression Orthosis with Electromagnetic Brake

Pathological tremor is a common neurological movement disorder characterized by involuntary rhythmic oscillation of body parts. Available treatments are often insufficiently effective or are accompanied by severe side effects. This work proposes a lightweight, portable elbow tremor suppression orthosis using an electromagnetic brake (EB) with on-off actuation scheme. The device reduces tremor a...

متن کامل

Evaluation of a wearable orthosis and an associated algorithm for tremor suppression.

We describe a wearable orthosis and an associated algorithm for the simultaneous assessment and treatment of essential tremor, one of the most common movement disorders in humans involving an overactivity of the olivo-cerebellar pathways. A motor providing effective viscosity is fixed on a wearable orthosis in the upper limbs. The motor is controlled by a personal computer with software process...

متن کامل

The immediate effect of orthotic management on grip strength of patients with lateral epicondylosis.

STUDY DESIGN Controlled laboratory study using a randomized crossover design. OBJECTIVE To determine the immediate effect of 3 common types of orthoses (2 elbow counterforce orthoses and a wrist splint) on grip strength in individuals with lateral epicondylosis. BACKGROUND Lateral epicondylosis is a common cause of pain and upper limb dysfunction. Although the effectiveness of orthoses has ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Frontiers in bioengineering and biotechnology

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016