Comparison of MR imaging breast coils.

نویسندگان

  • Norman B Konyer
  • Elizabeth A Ramsay
  • Michael J Bronskill
  • Donald B Plewes
چکیده

In one volunteer, five breast coils were evaluated for signal-to-noise ratio (SNR), uniformity, comfort, subject orientation, access to the breast, and unilateral imaging options. The four-coil arrays provided superior SNR, imaging flexibility, and access. Uniformity and comfort were issues with all coils. Substantial design differences exist between coils; purchasers should ensure that their specific requirements are met.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

Comparison between MRS and DWI in MRI of breast cancer

Introduction: Breast cancer is the most common cancer in women and is the second leading cause of cancer death (after lung cancer) in people throughout the world. Today, MRI is being used because of the limitations of x-ray mammography to detect breast cancer. Non-contrast sequences were associated to CE sequences in a breast MRI protocol for the sake of appraising morphologic ...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Switchable multicoil array for MR micro-imaging of breast lesions.

High-resolution breast imaging may improve differentiation between benign and malignant lesions and may be important for refining treatment strategy. This article presents a new, flexible design of a breast-imaging coil capable of providing breast images of a high level of spatial resolution. Referred to as a switchable coil array, the design uses small-diameter surface coils that provide high ...

متن کامل

A 7T ′′Capless′′ Transceive Breast Coil

Introduction Apart from being a non-invasive imaging modality, MR breast imaging can also provide high spatial and temporal resolution images of the breast, which is advantageous for fast and accurate diagnosis of disease. Studies have shown that it is possible to acquire high resolution breast images at ultra high fields with dedicated transceive RF breast coils that can transmit homogenous lo...