Valvular-ventricular interaction: importance of the mitral apparatus in canine left ventricular systolic performance.

نویسندگان

  • D E Hansen
  • P D Cahill
  • W M DeCampli
  • D C Harrison
  • G C Derby
  • R S Mitchell
  • D C Miller
چکیده

As the mitral valvular apparatus tenses during systole, forces transmitted along the chordae tendineae to the left ventricular chamber may influence left ventricular performance. To test this hypothesis, 10 dogs anesthetized with fentanyl were studied during cardiopulmonary bypass. The importance of the mitral apparatus in left ventricular systolic function was assessed independent of load by means of the slope of the contractile state-dependent left ventricular peak isovolumetric pressure-volume relationship (Emax), which was measured at constant heart rate and aortic pressure with a micromanometer inside a left ventricular intracavitary balloon before and immediately after all chordae tendineae were severed. Herniation of the balloon was prevented by a disk secured to the mitral anulus. Emax decreased from 11.97 +/- 3.35 (+/- SD) to 6.38 +/- 0.96 mm Hg/ml (p less than .001) with chordal severing. The volume intercept (Vo) was unchanged. Fluoroscopic studies of the balloon contour in eight additional dogs revealed dyskinesia in the area of the papillary muscle insertion and substantial alterations in chamber geometry during systole after the chordae were severed. Accordingly, we conclude that global left ventricular systolic performance is impaired when chordal attachments of the mitral valve are disrupted. Changes in left ventricular geometry or loss of inward force normally transmitted to the left ventricular wall as the valve tense may underlie these changes. These findings suggest that postoperative left ventricular dysfunction after mitral valve replacement may be attributable, in part, to excision of the native mitral apparatus at the time of surgery and support efforts to spare chordae during mitral valve surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal Value of Left Ventricular End-Systolic Elastance in Infants and Children

Background: In certain conditions, there is a need for a specific and improved measure of cardiac performance.  Routine methods for assessing left ventricular (LV) function are based on image-analysis or right heart monitoring which do not allow evaluation of ventriculo-arterial interaction. Chen et al presented a noninvasive method allowing measurement of end-systolic pressure–volume relation ...

متن کامل

Clinical and Electrocardiographic comparison of patients with primary Mitral Valve Prolapse Syndrome and control group

ABSTRACT: Mitral Valve Prolapse (WVP) in one of the commonest cardiac abnormalities. Echocardiography has generally been accepted as the diagnostic modality of choice, To assess the characteristic symptoms signs and electrocardiographic abnormalities of MVP results of prospective 500 age and sex matched healthy subjects without echocardiographic MVP (control subjects). The diagnostic criteria...

متن کامل

Physiologic role of the mitral apparatus in left ventricular regional mechanics, contraction synergy, and global systolic performance.

In animal models, severing the chordae tendineae of the mitral valve reduces the maximum global left ventricular elastance (Emax,g), a load-independent measure of left ventricular systolic performance; moreover, chamber geometry is altered with systolic bulging in the region of the papillary muscle insertions. This suggests that forces transmitted by the mitral apparatus increase the regional v...

متن کامل

Effect of disrupting the mitral apparatus on left ventricular function in dogs.

BACKGROUND The importance of the mitral apparatus to left ventricular function has been suggested in clinical studies. The effect of disruption of the mitral apparatus on left ventricular diastolic and systolic properties has not been fully documented. METHODS AND RESULTS We investigated the end-diastolic and end-systolic pressure-volume and stroke work-end-diastolic volume relations and meas...

متن کامل

Importance of mitral subvalvular apparatus in terms of cardiac energetics and systolic mechanics in the ejecting canine heart.

To assess the importance of the intact mitral subvalvular apparatus for left ventricular (LV) energetics, data from nine open-chest ejecting canine hearts were analyzed using piezoelectric crystals to measure LV volume. After mitral valve replacement with preservation of all chordae tendineae, baseline LV function was assessed during transient caval occlusion: A quadratic fit of the LV end-syst...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 73 6  شماره 

صفحات  -

تاریخ انتشار 1986