Accurate Mass Measurements of 26 Ne, 26−30 Na, 29−33 Mg Performed with the Mistral Spectrometer

نویسندگان

  • C. Gaulard
  • G. Audi
  • C. Bachelet
  • D. Lunney
  • M. de Saint Simon
  • C. Thibault
  • N. Vieira
چکیده

The minuteness of the nuclear binding energy requires that mass measurements be highly precise and accurate. Here we report on new measurements 29−33 Mg and 26 Na performed with the MISTRAL mass spectrometer at CERN's ISOLDE facility. Since mass measurements are prone to systematic errors, considerable effort has been devoted to their evaluation and elimination in order to achieve accuracy and not only precision. We have therefore conducted a campaign of measurements for calibration and error evaluation. As a result, we now have a satisfactory description of the MISTRAL calibration laws and error budget. We have applied our new understanding to previous measurements of 26 Ne, 26−30 Na and 29,32 Mg for which re-evaluated values are reported.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

European Organization for Nuclear Research Cern-ppe/95-175 30.11.1995 Mistral: a New Program for Precise Atomic Mass Determinations of Nuclides Far from Stability

The MISTRAL project (Mass measurements at ISOLDE using a Transmission Radio frequency spectrometer on-Line) is scheduled to begin experiments towards the end of 1996. With high resolution (105), potentially high accuracy (5 * 10-7) and excellent sensitivity (10 s-1), the MISTRAL spectrometer promises to provide needed mass measurements in regions of very-short lived nuclei. The spectrometer ope...

متن کامل

Measurements of the Ionic Charge States of Solar Energetic Particles Using the Geomagnetic Field

The mean charge states of C, N, O, Ne, Na, Mg, Al, Si, S, Ar, Ca, Fe, and Ni ions with 115–70 MeV nucleon in the two large solar energetic particle (SEP) events of 1992 October 30 and November 2 have been determined using measurements of the invariant latitude of the cosmic-ray cutoffs of these elements from the Mass Spectrometer Telescope on the polar-orbiting SAMPEX satellite. The deduced cha...

متن کامل

Iii. Chlorophyll Derivatives in Dsdp Leg 14, 20, 26, 27, and 29 Sediments

Electronic absorption spectra were obtained using a Beckman ACTA CIII ultraviolet-visible linear wavelength spectrophotometer and a Beckman DK-2 spectrophotometer. An Aminco-Bowman 8202 spectrophotofluorometer was employed for fluorescence measurements, and mass spectra were recorded using an AEI MS9 mass spectrometer equipped with a solid sample probe inlet system. The general procedure descri...

متن کامل

Long-term effects of growth hormone replacement in hypopituitary adults on body composition, bone mass and cardiovascular risk factors

6 Summary in Swedish 7 List of papers 8 Abbreviations 9 Introduction 10 Historical background 10 Initial GH treatment trials and dose titration 10 Quality of life 10 Effects of GH replacement on bone mass and density 11 Effects of GH replacement on muscle strength 12 Effects of GH replacement on body composition 12 Effects of GH replacement on glucose metabolism 13 Effects of GH replacement on ...

متن کامل

Evaluation of Anthracycline Effects on NT-ProBNP Plasma Level in Children with Malignancy

Background: NT-proBNP is a marker that is released from ventricles in response to pressure and volume overload. Raised plasma level of NT-proBNP is seen in ventricular dysfunction, ventricular muscular mass reduction or ventricular ischemia. Anthracyclines are widely used in treatment of pediatric cancer but their use is associated with cardiotoxicity which increases mortality and morbidity. We...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005