A plea for the single-lead ICD with atrial sensing due to anatomical considerations.

نویسندگان

  • C Fastner
  • M Behnes
  • J Kuschyk
  • I Akin
چکیده

We present the case of a 46-year old male patient suffering from non-ischemic cardiomyopathy and intermittent atrial tachycardia. According to guidelines an implantable cardioverter defibrillator (ICD) was planned to implant through the left subclavian vein. During the procedure the angiography revealed a persistent left superior vena cava (PLSVC) with moderate stenosis of the subclavian vein. Due to this we decided not to implant a dual chamber ICD but to implant a single chamber lead with additional atrial sensing capacity. The procedure as well as the follow-up was uneventful. Follow-up revealed good ventricular as well as atrial signals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

"Two for the Price of One": A Single-Lead Implantable Cardioverter-Defibrillator System with a Floating Atrial Dipole.

In patients known to be a high risk for sudden cardiac arrest, implantable cardioverter defibrillators (ICD) are a proven therapy to reduce risk of death. However, in patients without conventional indications for pacing, the optimal strategy for type of device, dual- versus single-chamber, remains debatable. The benefit of prophylactic pacing in this category of patients has never been document...

متن کامل

Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy

In this case report, we look into the implant procedure of a single-lead ICD with floating atrial sensing dipole in a pregnant woman, without using fluoroscopy. This system benefits the proper positioning of the lead. This is possible thanks to the simultaneous display of both the atrial and ventricular dipoles on the electro-anatomical mapping system. This technique may be taken into considera...

متن کامل

Comparison of a Novel, Single-Lead Atrial Sensing System With a Dual-Chamber Implantable Cardioverter- Defibrillator System in Patients Without Antibradycardia Pacing Indications

Background—Supraventricular tachyarrhythmias are the main cause for inappropriate therapy by implantable cardioverterdefibrillators (ICDs). For better rhythm discrimination, an atrial electrogram is helpful and usually obtained from an additional atrial lead, even in the absence of sinus node or atrioventricular nodal disease. An A -ICD system with integrated atrial sensing rings mounted 15 to ...

متن کامل

Comparison of a novel, single-lead atrial sensing system with a dual-chamber implantable cardioverter-defibrillator system in patients without antibradycardia pacing indications: results of a randomized study.

BACKGROUND Supraventricular tachyarrhythmias are the main cause for inappropriate therapy by implantable cardioverter-defibrillators (ICDs). For better rhythm discrimination, an atrial electrogram is helpful and usually obtained from an additional atrial lead, even in the absence of sinus node or atrioventricular nodal disease. An A+-ICD system with integrated atrial sensing rings mounted 15 to...

متن کامل

Twiddler's syndrome in a patient with a single-chamber implantable cardioverter defibrillator.

A 67-year-old, obese, Caucasian female with a history of ischaemic dilated cardiomyopathy and ventricular fibrillation, underwent a single-chamber implantable cardioverter defibrillator (ICD) with a screw, in ventricular lead implantation. Appropriate sensing, pacing, and defibrillation thresholds were obtained at implantation. A chest X-ray after implantation demonstrated a proper lead positio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European review for medical and pharmacological sciences

دوره 19 7  شماره 

صفحات  -

تاریخ انتشار 2015