Reproducibility of carotid artery Doppler frequency measurements.
نویسندگان
چکیده
Doppler sonography of 29 extracranial carotid arteries was performed twice within three days or less. Angiography revealed stenoses with from 10 to 95% diameter reduction in 25 internal carotid arteries whereas four vessels were found to be normal. The systolic peak frequency of the internal carotid artery read from the Doppler spectrum (n = 29) could be reproduced very well. This was shown by a linear regression nearest the line of identical values with a coefficient of correlation r = 0.97 (p less than 0.001). Other values derived from the spectral analysis of the Doppler shift signal were not so well reproduced including the peak frequency ratio (systolic peak frequency of the internal carotid artery/systolic peak of the common carotid artery) (n = 22; r = 0.81; p less than 0.001). The mean frequencies read from the zero-crossing detector recordings (n = 20) could not be reproduced as demonstrated by a linear regression far away from the line of identical measurements with a coefficient of correlation r = 0.43 (p less than 0.05).
منابع مشابه
Reproducibility of Carotid Artery Doppler Frequency
Doppler sonography of 29 extracranial carotid arteries was performed twice within three days or less. Angiography revealed stenoses with from 10 to 95% diameter reduction in 25 internal carotid arteries whereas four vessels were found to be normal. The systolic peak frequency of the internal carotid artery read from the Doppler spectrum (n = 29) could be reproduced very well. This was shown by ...
متن کاملLumen reduction measurements of the internal carotid artery before and after Levovist enhancement: reproducibility and agreement with angiography.
Our aim was to assess reproducibility of three different lumen reduction measuring methods--North American Symptomatic Carotid Endarterectomy Trial, European Carotid Surgery Trial, and common carotid--using power Doppler and color Doppler sonography before and after Levovist enhancement. We included 20 symptomatic patients with mild or severe carotid disease. North American Symptomatic Carotid ...
متن کاملبررسی 291 مورد سونوگرافی داپلر کاروتید در بیماران کاندید CABG
Introduction: Doppler ultrasonography (DUS) is the most preferable method for screening of carotid artery disease in patients undergoing CABG. The purpose of this study was to investigate the frequency of carotid artery disease and determine the relation between known risk factors of atherosclerosis and rate of carotid artery narrowing in order to identify high-risk groups among patients schedu...
متن کاملCandida patients in a Jorjani center in Shahid Mohammadi Hospital of carotid Doppler sonnograghy findings in coronary artery Bypas grafting Bandar Abbas
Introduction: Nowadays caotid Dopplers sonography is gold standard for carotid artery screening in coronary aetery bypass grafting (CABG) candidates. This study was carried out in an angioplasty center in southern seaport in Iran to assesss theprevalence of artery stenosis and correlation of the atherosclerosis risk factor with the rate of artery stensis, and nence to define the high risk group...
متن کاملInterstudy reproducibility of three-dimensional volume-selective fast spin echo magnetic resonance for quantifying carotid artery wall volume.
PURPOSE To assess the interstudy reproducibility of a three-dimensional volume-selective, fast spin echo (FSE) magnetic resonance technique for the assessment of carotid artery wall volume, which is a marker for total carotid plaque volume. MATERIALS AND METHODS Interstudy reproducibility was evaluated in 10 subjects with evidence of carotid artery atherosclerotic disease on carotid Doppler u...