Simultaneous determination of Rabeprazole sodium and Domperidone

نویسندگان

  • Nesrin K. Ramadan
  • Azza A. Moustafa
  • Heba M. Mohamed
چکیده

Three simple and sensitive methods were developed for the determination of a mixture of Rabeprazole sodium RB and Domperidone DP without prior separation. The first method A, isoabsorptive point comprised of measurement the total content of the mixture at their isoabsorptive point, while the content of RB was determined by measuring the first order derivative of its spectra at 231 nm, and the content of DP could be calculated by subtraction. The second method, B was based on the mean centering of ratio spectra, the concentration of RB was determined by measuring the amplitude at 256.4 nm and the concentration of DP was determined by measuring the amplitude at 311.8 nm. The third method C, dual wavelength method, the wavelengths selected for determination of Rabeprazole were 270 nm & 301 nm, whereas, the wavelengths selected for determination of Domperidone were 260 and 297.2 nm. The percentages mean accuracy for RB were 99.74 ± 0.498 % for method (A), 100.52 ± 0.478 % for (B) and 100.43 ± 0.502 % for (C) respectively. And that of DP were 100.28 ± 0.488 % for method (A), 99.24 ± 0.551 % for (B) and 99.95 ± 0.516 % for (C) respectively. The obtained results were statistically compared with those obtained by the official methods, showing no significant difference with respect to accuracy and precision.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Spectrophotometric Estimation of Rabeprazole Sodium and Domperidone Maleate in their Combined Pharmaceutical

Two simple, rapid, economical, specific, precise and accurate spectrophotometric methods have been developed for simultaneous estimation of rabeprazole sodium and domperidone maleate in their combined pharmaceutical dosage forms. Rabeprazole sodium and domperidone shows absorption maxima at 285 nm and 287 nm respectively. The first method is based on the simultaneous equations. In the simultane...

متن کامل

Quality Control and Standardization of Rabeprazole Tablets

Rabeprazole sodium is a new stable pharmaceutical composition developed by us in tablet form, consisting of rabeprazole sodium as active ingredient, excipients, a separating layer and enteric coating. The manufacturing method involves pressing with preliminary wet granulation. In this work, a method was developed for the quantitative determination of rabeprazole sodium in tablets with simultane...

متن کامل

Spectrophotometric methods for simultaneous estimation of rabeprazole sodium and aceclofenac from the combined capsule dosage form

INTRODUCTION The present work aimed to develop and validate spectrophotometric methods for simultaneous estimation of rabeprazole sodium and aceclofenac in a pure and capsule dosage form. MATERIALS AND METHODS Method 1 is based on solving a simultaneous equation. Absorbances of rabeprazole sodium and aceclofenac were measured at their respective absorbance maximas (λ max) of 283 and 276 nm. M...

متن کامل

Design, Development and In-Vitro Evaluation of Floating Bilayer Tablet of Domperidone and Rabeprazole for the Treatment of Gastro Esophageal Reflux Disorder

Bilayer tablets of Domperidone (IR) Rabeprazole (SR) were formulated for the management of gastro esophageal disorder.Immediate layer of Domperidone formulated using Tulsion T-339 as super disintegrant. For sustained release of Rabeprazole HPMC as the rate controlling polymers was used. Preformulation studies were performed prior to compression. The individual layers of the bilayer tablets were...

متن کامل

Spectrophotometric Determination of Drugs Using Iodine As Analytical Reagent

Six drugs viz., Astemizole, Cisapride, Domperidone, Pantoprazole, Rabeprazole and Trazadone were tested for the formation of charge transfer complexes with Iodine. Each of these drugs turned the violet coloured i.e iodine , in CH2Cl2, to brown and exhibited a new band at 366nm in addition to the original band of iodine at 510nm due to anion of the reagent whose intensity increased with increase...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011