Chiral separation of deprenyl-N-oxide isomers by capillary electrophoresis using various cyclodextrin derivatives.

نویسندگان

  • Tamás Tábi
  • Attila Sándor Halász
  • Melinda Pálfi
  • Kálmán Magyar
  • Eva Szöko
چکیده

Chiral separation of deprenyl-N-oxide isomers is presented using capillary electrophoresis in the presence of various cyclodextrin (CD) derivatives. This recently identified metabolite of R-(-)-deprenyl may possess desirable pharmacological activities. The effect of the cavity size and the substituents of the CD are examined on the enantiomer resolution of the compound having an asymmetric center on a heteroatom. The importance of hydrophilic or hydrogen bonding interaction, as well as the position of the interacting groups is demonstrated. Outstanding selectivity and resolution values are achieved using the chargeable carboxymethyl-beta-CD. 2-Hydroxypropyl-beta-CD is also suitable for the enantiomer separation of the analyte. Native beta-CD and carboxyethyl-beta-CD provide only poor enantioselectivity, whereas heptakis-(2,6-di-O-methyl)-beta-CD is capable of separating only the diastereomers. No chiral resolution can be observed in the presence of gamma-CD.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Guanidine Hcl to Improve Enantioseparation of a Model Basic Drug, Cetirizine, By Capillary Electrophoresis Using Sulfated Β-Cyclodextrin

A common approach in resolving enantiomers of chiral basic drugs by capillary electrophoresis (CE) is to use cyclodextrins (especially their anionic derivatives) as chiral selector in the acidic buffer (pH ≤ 3) in normal or reversed (carrier) mode. Then, some organic modifiers are added to the buffer solution if the resolution is not satisfactory. In case of cetirizine (CTN), applying the same ...

متن کامل

Application of Guanidine Hcl to Improve Enantioseparation of a Model Basic Drug, Cetirizine, By Capillary Electrophoresis Using Sulfated Β-Cyclodextrin

A common approach in resolving enantiomers of chiral basic drugs by capillary electrophoresis (CE) is to use cyclodextrins (especially their anionic derivatives) as chiral selector in the acidic buffer (pH ≤ 3) in normal or reversed (carrier) mode. Then, some organic modifiers are added to the buffer solution if the resolution is not satisfactory. In case of cetirizine (CTN), applying the same ...

متن کامل

Separation of racemic sulfoxides and sulfinate esters on four derivatized cyclodextrin chiral stationary phases using capillary gas chromatography.

The separation of 17 chiral sulfoxides and eight chiral sulfinate esters by gas chromatography (GC) on four derivatized cyclodextrin chiral stationary phases (CSPs) (Chiraldex G-TA, G-BP, G-PN, B-DM) is presented. Many of these compounds are structural isomers or part of a homologous series. Differences in enantioselectivity of the methyl phenyl sulfoxide isomers on the derivatized gamma cyclod...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 42 1  شماره 

صفحات  -

تاریخ انتشار 2004