Penalty factor-based optimization algorithm for distributed generation sizing in distribution network

نویسندگان

  • Jasrul Jamani JAMIAN
  • Mohd Nabil MUHTAZARUDDIN
  • Muhammad Ariff BAHARUDIN
چکیده

The installation of distributed generation (DG) can be used to minimize the total power loss in the distribution network. Besides that, other power system performances such as voltage profile, stability index, and total harmonic distortion can also be improved via DG. Although many works on DG have been done, most researchers have assumed that the distribution line is in an ideal condition (unlimited capacity limit). On the contrary, all practical lines should have their own capacity limit. Therefore, the main contribution of this paper is to determine the optimal DG output that can fulfill the maximum allowable line capacity limit (MALCL). Furthermore, a penalty factor in rank evolutionary particle swarm optimization analysis is also proposed to handle the constraint. A 33-bus distribution system is used as a test system to investigate the performance of the optimization technique. The results showed that the line capacity increment caused by optimal DG output is always less than the MALCL value. Furthermore, the total power loss value in the system is increased when the MALCL set by utility is reduced. In terms of optimization performance, the proposed algorithm gives faster computing time and consistent results compared to conventional particle swarm optimization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using the Modified Shuffled Frog Leaping Algorithm for Optimal Sizing and location of Distributed Generation Resources for Reliability Improvement

Restructuring the recent developments in the power system and problems arising from construction as well as the maintenance of large power plants lead to increase in using the Distributed Generation (DG) resources. DG units due to its specifications, technology and location network connectivity can improve system and load point reliability indices. In this paper, the allocation and sizing of di...

متن کامل

Optimal Placement and Sizing of Distributed Generation Via an Improved Nondominated Sorting Genetic Algorithm II

The use of distributed generation units in distribution networks has attracted the attention of network managers due to its great benefits. In this research, the location and determination of the capacity of distributed generation (DG) units for different purposes has been studied simultaneously. The multi-objective functions in the optimization model are reducing system line losses; reducing v...

متن کامل

Optimal Location and Sizing of Distributed Generations in Distribution Networks Considering Load Growth using Modified Multi-objective Teaching Learning Based Optimization Algorithm

Abstract: This paper presents a modified method based on teaching learning based optimization algorithm to solve the problem of the single- and multi-objective optimal location of distributed generation units to cope up the load growth in the distribution network .Minimizing losses, voltage deviation, energy cost and improved voltage stability are the objective functions in this problem. Load g...

متن کامل

A New Optimization Algorithm for Optimal Wind Turbine Location Problem in Constantine City Electric Distribution Network Based Active Power Loss Reduction

The wind turbine has grown out to be one of the most common Renewable Energy Sources (RES) around the world in recent years. This study was intended to position the Wind Turbine (WT) on a wind farm to achieve the highest performance possible in Electric Distribution Network (EDN). In this paper a new optimization algorithm namely Salp Swarm Algorithm (SSA) is applied to solve the problem of opt...

متن کامل

Optimal placement and sizing of distributed generation considering FACTS devices and load uncertainty using hybrid sine-cosine algorithm and particle swarm optimization (HSCA-PSO)

Using Distributed Generation (DG) in electrical distribution networks brings many advantages and thus, optimal placement and sizing of these units become important. Most of the researches in this field neglect the effect of transmission system on distribution section. These researches also ignore the effect of Flexible Alternating Current Transmission Systems (FACTS). This thesis proposes a new...

متن کامل

A SAIWD-Based Approach for Simultaneous Reconfiguration and Optimal Siting and Sizing of Wind Turbines and DVR units in Distribution Systems

In this paper, a combination of simulated annealing (SA) and intelligent water drops (IWD) algorithm is used to solve the nonlinear/complex problem of simultaneous reconfiguration with optimal allocation (size and location) of wind turbine (WT) as a distributed generation (DG) and dynamic voltage restorer (DVR) as a distributed flexible AC transmission systems (DFACT) unit in a distribution sys...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016