Improving the sensitivity of the Xpert MTB/RIF assay on sputum pellets by decreasing the amount of added sample reagent: a laboratory and clinical evaluation.

نویسندگان

  • Nila J Dharan
  • Danielle Amisano
  • Gerald Mboowa
  • Willy Ssengooba
  • Robert Blakemore
  • Rachel W Kubiak
  • Derek T Armstrong
  • Martin Jones
  • Yukari C Manabe
  • Moses L Joloba
  • Jerrold J Ellner
  • Susan E Dorman
  • David Alland
چکیده

The Xpert MTB/RIF (Xpert) assay permits rapid near-patient detection of Mycobacterium tuberculosis in sputum; however, the test sensitivity remains suboptimal in paucibacillary specimens that are negative for acid-fast bacilli using smear microscopy. Xpert testing includes dilution with sample reagent, and when processed sputum pellets are tested, the recommended sample reagent/pellet ratio is 3:1. We evaluated whether a decreased sample reagent/pellet ratio of 2:1 increased Xpert sensitivity compared to the recommended 3:1. The limit of detection was determined by inoculating serial dilutions of M. tuberculosis into sputum samples, preparing sputum pellets, and testing each pellet by Xpert at both sample reagent ratios. Processed sputum pellets obtained from M. tuberculosis culture-positive clinical specimens were also tested by Xpert at both ratios. Among spiked sputum pellets, the limit of detection was 1,478 CFU/ml (95% confidence interval [CI], 1,211 to 1,943) at a 3:1 ratio and decreased to 832 CFU/ml (95% CI, 671 to 1,134) at 2:1. The proportion of specimens in which M. tuberculosis was detected was greater at 2:1 than at 3:1 for almost all numbers of CFU/ml; this difference was most prominent at lower numbers of CFU/ml. Among 134 concentrated sputum pellets from the clinical study, the sensitivity of Xpert at 2:1 was greater than at 3:1 overall (80% versus 72%; P=0.03) and for smear-negative specimens (67% versus 58%; P=0.12). For Xpert testing of sputum pellets, using a lower sample reagent/pellet ratio increased M. tuberculosis detection, especially for paucibacillary specimens. Our study supports use of a 2:1 sample reagent/pellet dilution for Xpert testing of sputum pellets.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid and Accurate Detection of Mycobacterium tuberculosis in Sputum Samples by Cepheid Xpert MTB/RIF Assay—A Clinical Validation Study

BACKGROUND A crucial impediment to global tuberculosis control is the lack of an accurate, rapid diagnostic test for detection of patients with active TB. A new, rapid diagnostic method, (Cepheid) Xpert MTB/RIF Assay, is an automated sample preparation and real-time PCR instrument, which was shown to have good potential as an alternative to current reference standard sputum microscopy and cultu...

متن کامل

Accuracy of different Xpert MTB/Rif implementation strategies in programmatic settings at the regional referral hospitals in Uganda: Evidence for country wide roll out

BACKGROUND Xpert MTB/RIF assay is a highly sensitive test for TB diagnosis, but still costly to most low-income countries. Several implementation strategies instead of frontline have been suggested; however with scarce data. We assessed accuracy of different Xpert MTB/RIF implementation strategies to inform national roll-out. METHODS This was a cross-sectional study of 1,924 adult presumptive...

متن کامل

Evaluation of Xpert® MTB/RIF Assay in Induced Sputum and Gastric Lavage Samples from Young Children with Suspected Tuberculosis from the MVA85A TB Vaccine Trial

OBJECTIVE Diagnosis of childhood tuberculosis is limited by the paucibacillary respiratory samples obtained from young children with pulmonary disease. We aimed to compare accuracy of the Xpert® MTB/RIF assay, an automated nucleic acid amplification test, between induced sputum and gastric lavage samples from young children in a tuberculosis endemic setting. METHODS We analyzed standardized d...

متن کامل

Improved performance of Xpert MTB/RIF assay on sputum sediment samples obtained from presumptive pulmonary tuberculosis cases at Kibong’oto infectious diseases hospital in Tanzania

BACKGROUND The introduction of Xpert MTB/RIF assay (Xpert) has significantly improved diagnosis of Tuberculosis (TB) in resource limited human immunodeficiency virus (HIV) endemic settings. We aimed to modify the Xpert protocol to improve the detection of Mycobacterium tuberculosis (MTB). METHODS This cross sectional study was conducted among presumptive pulmonary tuberculosis (PTB) patients ...

متن کامل

The New Xpert MTB/RIF Ultra: Improving Detection of Mycobacterium tuberculosis and Resistance to Rifampin in an Assay Suitable for Point-of-Care Testing

The Xpert MTB/RIF assay (Xpert) is a rapid test for tuberculosis (TB) and rifampin resistance (RIF-R) suitable for point-of-care testing. However, it has decreased sensitivity in smear-negative sputum, and false identification of RIF-R occasionally occurs. We developed the Xpert MTB/RIF Ultra assay (Ultra) to improve performance. Ultra and Xpert limits of detection (LOD), dynamic ranges, and RI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 53 4  شماره 

صفحات  -

تاریخ انتشار 2015