OBJECTIVES This study describes the process of tissue electroforming and how shape changes in cartilage can be produced by the application of direct current (DC). The dependence of shape change on voltage and application time is explored. STUDY DESIGN Basic investigation using ex vivo porcine septal cartilage grafts and electromechanical cartilage deformation focused on development of a new surgical technique. METHODS Uniform flat porcine nasal septal cartilage specimens were mechanically deformed between two semicircular aluminum electrodes. DC current was applied to establish charge separation and electrical streaming potential. Voltage (0-3.5 V) and application time (0-5 minutes) were varied. Shape change was measured, and shape retention was calculated using analytic representation. The effect of the direction of applied current on shape change was evaluated by switching the polarities of electrodes and using parameters of 0 to 5.5 V and 5 minutes. Temperature during reshaping was monitored with a thermocouple, and surface features were evaluated using light microscopy. RESULTS Reshaped specimen demonstrated mechanical stability similar to native cartilage tissue. Shape retention strongly correlated with increasing voltage and application time. Only a small current (<0.1 A) through the tissue was measured. Temperature change was less than 2 degrees C during electroforming, suggesting that electroforming likely results from some nonthermal mechanisms. Surface features indicated that electrodeposition may occur depending on electrode material and magnitude of the applied voltage. CONCLUSIONS These findings demonstrate that cartilage can be reshaped through the process we have described as "electroforming" by generating intrinsic differences in charge separation with negligible heat production.
منابع مشابه
Changes in the tangent modulus of rabbit septal and auricular cartilage following electromechanical reshaping.
Transforming decades' old methodology, electromechanical reshaping (EMR) may someday replace traditionally destructive surgical techniques with a less invasive means of cartilage reshaping for reconstructive and esthetic facial surgery. Electromechanical reshaping is essentially accomplished through the application of voltage to a mechanically deformed cartilage specimen. While the capacity of ...
متن کاملComparison of bend angle measurements in fresh cryopreserved cartilage specimens after electromechanical reshaping
Cryopreservation of cartilage has been investigated for decades and is an established protocol. However, the reliability and application of cryopreservation of cartilage for use in electromechanical reshaping (EMR) has not been studied exclusively. A system to cryopreserve large amounts of tissue provides a steady source of similar quality cartilage for future experimentation. This will reduce ...
متن کاملThe Effect of pH on Rabbit Septal Cartilage Shape Change: Exploring the Mechanism of Electromechanical Tissue Reshaping
INTRODUCTION Electromechanical reshaping (EMR) involves the application of an electrical current to mechanically deformed cartilage to create sustained tissue shape change. Although EMR may evolve to become an inexpensive and reliable way of producing shape change in cartilage during reconstructive surgery, the precise mechanism of EMR is unknown. We aim to examine the isolated effect of proton...
متن کاملUsing optical coherence tomography to monitor effects of electromechanical reshaping in septal cartilage
Electromechanical reshaping (EMR) of cartilage is a promising noninvasive technique with potential for broad application in reconstructive surgery. EMR involves applying direct current electrical fields to localized stress regions and then initiating a series of oxidation-reduction reactions, thus effecting a shape change. Previous EMR studies have focused on macroscopic structural measurements...
متن کاملIn-depth analysis of pH-dependent mechanisms of electromechanical reshaping of rabbit nasal septal cartilage.
OBJECTIVES/HYPOTHESIS Electromechanical reshaping (EMR) involves reshaping cartilage by mechanical deformation and delivering electric current to the area around the bend axis, causing local stress relaxation and permanent shape change. The mechanism of EMR is currently unclear, although preliminary studies suggest that voltage and application time are directly related to the concentration and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Laryngoscope
دوره 113 11 شماره
صفحات -
تاریخ انتشار 2003