Three-dimensional transesophageal echocardiography of the atrial septal defects

نویسندگان

  • Francisco-Javier Roldán
  • Jesús Vargas-Barrón
  • Clara Vázquez-Antona
  • Luis Muñoz Castellanos
  • Julio Erdmenger-Orellana
  • Ángel Romero-Cárdenas
  • Marco-Antonio Martínez-Ríos
چکیده

Transesophageal echocardiography has advantages over transthoracic technique in defining morphology of atrial structures. Even though real time three-dimensional echocardiographic imaging is a reality, the off-line reconstruction technique usually allows to obtain higher spatial resolution images. The purpose of this study was to explore the accuracy of off-line three-dimensional transesophageal echocardiography in a spectrum of atrial septal defects by comparing them with representative anatomic specimens.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imaging Atrial Septal Defects by Real-Time 3D Transesophageal Echocardiography: Step-by-Step Approach

Background: There are currently no standardized three-dimensional (3D) transesophageal echocardiographic (TEE) views of the interatrial septum and atrial septal defects (ASDs). Without a standardized approach, it is difficult to ascertain the important anatomic relationships (such as the location of the aortic rim of an ASD), to perform relevant measurements (such as the size of an ASD or the s...

متن کامل

Horseshoe-like Shaped Atrial Septal Defects Confirmed on Three-Dimensional Transesophageal Echocardiography

A 51-year-old female with exertional dyspnea was admitted. Transthoracic echocardiography (TTE) revealed 2 defects at interatrial septum with left to right shunt (Fig. 1A). En face display of the interatrial septum by three-dimensional (3D) TTE demonstrated two ovoid atrial septal defects (ASDs). Two ovoid defects and interatrial septum formed like horseshoe (Fig. 1B). Transesophageal echocardi...

متن کامل

Cor Triatriatum Sinister diagnosed in adult life with three dimensional transesophageal echocardiography

BACKGROUND Cor triatriatum is a very rare congenital abnormality, usually symptomatic during childhood, diagnosis in adult age is less common. CASE PRESENTATION We report the case of a 40 years old woman referred to our hospital for atrial flutter ablation, transthoracic cardiac bidimensional echocardiography showed an abnormal membrane bisecting the left atrium, the diagnosis of cor triatria...

متن کامل

Echocardiographic guidance during placement of the buttoned double-disk device for atrial septal defect closure.

The usefulness of two-dimensional and Doppler echocardiography during buttoned double-disk device closure of an atrial septal defect was evaluated in 20 consecutive patients at the time of interventional catheterization. Transesophageal echocardiography was used in 11 patients (ages 5 to 62 years, weights 20 to 91 kg). Because of the size of the available transesophageal echo probe, transthor...

متن کامل

Live/Real Time Three-Dimensional Trans Esophageal Echocardiographic Findings in Amplatzer ASD Closure Devices in Adults

Six female patients aged from 19 to 73 years, with ostium secundum atrial septal defect underwent closure procedure with Amplatzer septal occluder device. Three-dimensional Echocardiography (3D-TEE) was done during the procedure or one day after the procedure. 3D-TEE provides incremental value over Two- dimensional trans-esophageal echocardiography in measuring Amplatzer septal occluder disc si...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cardiovascular Ultrasound

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2008