ZnO Film Bulk Acoustic Resonator for the Kinetics Study of Human Blood Coagulation

نویسندگان

  • Da Chen
  • Zhen Zhang
  • Jilong Ma
  • Wei Wang
چکیده

Miniaturized and rapid blood coagulation assay technologies are critical in many clinical settings. In this paper, we present a ZnO film bulk acoustic resonator for the kinetic analysis of human blood coagulation. The resonator operated in thickness shear resonance mode at 1.4 GHz. When the resonator contacted the liquid environment, the viscous loading effect was considered as the additional resistance and inductance in the equivalent circuits, resulting in a linear relationship with a slope of approximately -217 kHz/cP between the liquid viscosity and the frequency of the resonator. The downshift of the resonant frequency and the viscosity change during the blood coagulation were correlated to monitor the coagulation process. The sigmoidal trend was observed in the frequency response for the blood samples activated by thromboplastin and calcium ions. The coagulation kinetics involving sequential phases of steady reaction, growth and saturation were revealed through the time-dependent frequency profiles. The enzymatic cascade time, the coagulation rate, the coagulation time and the clot degree were provided by fitting the time-frequency curves. The prothrombin times were compared with the results measured by a standard coagulometer and show a good correlation. Thanks to the excellent potential of integration, miniaturization and the availability of direct digital signals, the film bulk acoustic resonator has promising application for both clinical and personal use coagulation testing technologies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Film bulk acoustic-wave resonator based ultraviolet sensor

This letter described ultraviolet UV radiation sensing with ZnO based film bulk acoustic-wave resonator FBAR . The resonant frequency upshifted when there was UV illumination on the FBAR. For 365 nm UV light, the frequency upshift was 9.8 kHz with an intensity of 600 W /cm2, and the detection limit of the sensor was 6.5 nW. The frequency increase in the FBAR UV sensor was proposed to be due to ...

متن کامل

High Frequency Thin Film Acoustic Ferroelectric Resonators

Both ZnO and PZT Thin Film Bulk Acoustic Resonator filters were fabricated, tested and modeled in this study. The development of an accurate Mason model allows the effect of particular parasitic components on the microwave s-parameters in the region of the series and parallel resonances to be identified. The parasitic components that limit the performance of our ZnO and PbZr0.3Ti0.7O3 Thin Film...

متن کامل

Thin-Film Bulk Acoustic Resonators and Filters Using ZnO and Lead–Zirconium–Titanate Thin Films

This paper presents the findings of a design, modeling, and fabrication study of ZnO and PbZr0 3Ti0 7O3 thin-film bulk acoustic resonators and filters. Measurements of the high-frequency responses of ZnO resonators having different area are used to develop an acoustic model that accurately represents resonator impedance data. The models are also used to interpret -parameter measurements on thin...

متن کامل

Tunable coupled surface acoustic cavities

Related Articles Extremely low-loss acoustic phonons in a quartz bulk acoustic wave resonator at millikelvin temperature Appl. Phys. Lett. 100, 243504 (2012) Extraction of second order piezoelectric parameters in bulk acoustic wave resonators Appl. Phys. Lett. 100, 232901 (2012) Acoustic resonator based on periodically poled transducers: Concept and analysis J. Appl. Phys. 111, 064106 (2012) Vi...

متن کامل

Streptavidin Modified ZnO Film Bulk Acoustic Resonator for Detection of Tumor Marker Mucin 1

A ZnO-based film bulk acoustic resonator has been fabricated using a magnetron sputtering technology, which was employed as a biosensor for detection of mucin 1. The resonant frequency of the thin-film bulk acoustic resonator was located near at 1503.3 MHz. The average electromechanical coupling factor [Formula: see text] and quality factor Q were 2.39 % and 224, respectively. Using the specifi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017