Increasing occlusal surface thickness of stainless steel crowns: a clinical technique.

نویسنده

  • T P Croll
چکیده

Patients with tooth grinding habits may tend to wear through the occlusal surfaces of stainless steel crowns. A technique is described which prevents this problem by increasing metal occlusal surface thickness of the crown.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro analysis of the marginal adaptation and discrepancy of stainless steel crowns

Aim: The purpose of the study was to assess the marginal adaptation and discrepancy of SSC's. Differences in adaptation and discrepancy between the four surfaces (mesial, lingual, distal, and buccal) were evaluated. Methods: The placement of stainless steel crowns were completed on a phantom head in accordance with the clinical technique. The ideal tooth preparation was made and this 'master to...

متن کامل

Wear and repair of stainless steel crowns.

AIM The purpose of this study was to determine the wear of stainless steel crowns (SSCs) in children, and compare the extent of microleakage in SSCs that had been repaired using either a cermet glass-ionomer cement (GIC) or a packable composite resin (CR). MATERIALS AND METHODS For the first aim, the occlusal surface thickness of 31 harvested SSCs (21 primary first and 10 second molars) and 1...

متن کامل

بررسی میزان تغییر محیط و ضخامت لبه روکشهای استنلس استیل از پیش فرم گرفته (Precrimped)، بعد از Recrimping

Background and Aim: The need for recrimping precrimped stainless steel crowns by the dentist in clinic is controversial. This study aimed to evaluate the rate of marginal circumference and marginal thickness change of precrimped stainless steel crowns after recrimping. Materials and Methods: In this experimental study, 30 primary photos were taken from margins of 30 S.S.Cs (3M, Ni-Cr) related t...

متن کامل

Effects of polycarboxylate and glass ionomer cements on stainless steel crown retention.

Retentive properties of three dental cements were tested using stainless steel crowns Fitted to extracted third molar teeth. No significant difference was Found between the overall mean retentive Forces of the polycarboxylate cement and the two glass ionomer cements. Mechanical retention of the crowns was not a Factor in the overall retentive value. Few studies have investigated the retention o...

متن کامل

The repair of preveneered posterior stainless steel crowns.

PURPOSE This study's purposes were to determine the shear bond strength (SBS) for and to perform dye penetration (microleakage) and scanning electron microscopy (SEM) evaluations of preveneered posterior stainless steel crowns (SSCs) that were repaired using 2 different materials. METHODS Twenty-two crowns were used. They were stored in artificial saliva for 30 days and then thermocycled. A f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pediatric dentistry

دوره 2 4  شماره 

صفحات  -

تاریخ انتشار 1980