Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

نویسنده

  • Ruth Hearn
چکیده

Rapid semiquantitative elemental screening of pharmaceutical samples is described using the Agilent 7500ce ICP-MS with helium as collision gas. Polyatomic interferences are eliminated in the He pressurized cell, enabling rapid elemental profiling of pharmaceutical tablets for screening purposes. Elements which normally suffer from polyatomic interferences have been included in the semiquantitative analysis and trace metal profiles obtained for the pharmaceutical tablets from three different batches agreed with those obtained by fully quantitative analysis. The method has potential therefore as a fast analytical tool in the pharmaceutical manufacture chain. Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unmatched Removal of Spectral Interferences in ICP-MS Using the Agilent Octopole Reaction System with Helium Collision Mode Application

Many routine laboratories have adopted ICP-MS as their primary technique for metals analysis due to its simple operation as a multi-element analyzer. However, despite its higher performance for the targeted removal of specific interferences, collision/reaction cell (CRC) ICP-MS remains relatively understudied in terms of its multielement capability. This work demonstrates that the Agilent 7500c...

متن کامل

The Use of Collision/Reaction Cell ICP-MS with Isotope Dilution to Provide Assigned Values for Zn, Cu, and Se in Serum Samples for a Proficiency Testing Scheme

This work describes a procedure for the determination of copper, selenium, and zinc in serum using the Agilent 7500ce collision/reaction cell (CRC) ICP-MS in both helium and hydrogen modes. The method utilizes the high-accuracy technique of isotope dilution whereby the sample is spiked with an isotopically enriched solution to an optimum ratio and measured alongside a spiked calibration standar...

متن کامل

Direct Elemental Analysis of Gasoline by Agilent 7500ce ORS ICP-MS Application

The Agilent 7500ce ICP-MS is shown to be an excellent analytical tool for the elemental analysis of gasoline. It offers the best detection limits of any multi-element technique and a full elemental analysis suite that takes less than 5 minutes to acquire. The Octopole Reaction System (ORS), integral to the 7500ce, ensures that a single method and set of conditions can be used to directly determ...

متن کامل

Multi-Element Determination of Heavy Metals in Dietary Supplements Using Collision/Reaction Cell ICP-MS Application

Determination of 11 metals (including arsenic, chromium, mercury, iron, copper, nickel, zinc, selenium, lead, cadmium, and thallium) in UK-consumed dietary supplements was carried out using ICP-MS. The instrument used was the Agilent 7500ce, which is equipped with a collision/ reaction cell (Octopole Reaction System), and was operated in no-gas, helium, and hydrogen modes, all acquired within a...

متن کامل

Accurate Quantification of Cadmium, Chromium, Mercury and Lead in Plastics for RoHS Compliance using the Agilent 7500ce ICP-MS

This application note describes the quantification of cadmium, chromium, lead and mercury in plastic materials by external calibration using the Agilent 7500ce ICP-MS system equipped with an Octopole Reaction System (ORS). Isotope dilution analysis with ICP-MS was used as a confirmatory technique. Good agreement of the results obtained by the two calibration approaches was achieved. The sample ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017