ALTERNATIVE GAS TO SF 6 FOR USE IN HIGH VOLTAGE SWITCHGEARS : g 3

نویسندگان

  • Yannick KIEFFEL
  • François BIQUEZ
  • Philippe PONCHON
چکیده

The modern transmission and distribution network relies on SF6 technology because of its remarkable arc quenching properties and dielectric insulation (approximately 3 times greater than air). However, even if SF6 Switchgears are safe for the environment, the SF6 insulating gas has potential significant environmental impacts if it leaks into the atmosphere. Indeed SF6 is one of the six gases listed in the Kyoto Protocol, with a global warming potential that is 23500 times greater than CO2. Alternative solutions to SF6 have been researched for a long time. Up to now, no significant success has been achieved in solutions for the transmission network. This paper presents the research conducted with fluorinated compounds to qualify a new gas to be used into high voltage equipment as SF6 alternatives with properties significantly improved with respect to typical SF6/N2 mixtures or others already in use. Potential applications of SF6-free gas mixture, called g 3 and based on 3M TM Novec TM 4710 Dielectric Fluid for dielectric insulation and arc switching into high voltage apparatuses are reported with the aim to be low in toxicity and to reduce the global warming potential of the new mixture by more than 98% by respect to SF6 with no or minor design modification by respect to typical SF6 design. Research in progress on arc interrupting capability of this new gas mixture has shown promising results. We expect this new gas mixture to allow a major move towards a new generation of environmentally friendly switchgears

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Breakdown Characteristics of SF6/CF4 Mixtures in Test Chamber and 25.8kV GIS

SF 6 gas has excellent dielectric strength, but it causes global warming about 23900 times more than CO 2 gas which is the main cause of global warming. This shows necessity of the environment friendly dielectric gas which can replace SF 6 gas. We made the test chamber which simulated inner of the gas insulation switchgear (GIS) and 25.8kV GIS of 3 phase unity bundle operation tank type. The br...

متن کامل

An UWB Printed Antenna for Partial Discharge UHF Detection in High Voltage Switchgears

As important fundamental equipment, high voltage switchgears are widely used in electric power systems and directly relative to the power reliability and quality. Partial discharge (PD) online monitoring is one of the most effective methods used for insulation testing and diagnosis in high voltage switchgears and power systems. This paper proposes a unique ultra-wide-band (UWB) antenna with hig...

متن کامل

Investigation of Gas-Sensing Property of Acid-Deposited Polyaniline Thin-Film Sensors for Detecting H2S and SO2

Latent insulation defects introduced in manufacturing process of gas-insulated switchgears can lead to partial discharge during long-time operation, even to insulation fault if partial discharge develops further. Monitoring of decomposed components of SF₆, insulating medium of gas-insulated switchgear, is a feasible method of early-warning to avoid the occurrence of sudden fault. Polyaniline th...

متن کامل

Inception Level of Partial Discharges in SF6 Induced with Short X-Ray Pulses

First generation gas insulated switchgears were constructed with large safety margin. Today’s trend is to reduce the size of the switchgears to save material and costs. With increased field strength due to reduced dimensions as well as increased pressure in the compartments, the influence of surface roughness, surface damages and conducting particles is increasing. Therefore the knowledge of th...

متن کامل

Lattice Boltzmann modeling of two component gas diffusion in solid oxide fuel cell

In recent years, the need for high efficiency and low emission power generation systems has made much attention to the use of fuel cell technology. The solid oxide fuel cells due to their high operating temperature (800 ℃ -1000 ℃) are suitable for power generation systems.Two-component gas flow (H2 and H2O) in the porous media of solid oxide fuel cell’s anode have been modeled via lattice Boltz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015