Detection of coliform organisms in drinking water by radiometric method.

نویسندگان

  • S J Khurshid
  • S Bibi
چکیده

The radiometric method has been used for detection of coliform bacteria in water. The method is based on measuring the released metabolic 14CO2 from 14C-lactose in growth media containing coliform organisms incubated at 37 degrees C under continuous shaking. This rapid and sensitive radiometric method permits the detection of even single coliform organisms within 6 hours of incubation. Using this automated method, a total of 102 samples (in duplicate) collected from different areas in and around Rawalpindi and Islamabad were assessed for coliform bacteria. Of these 102 samples, 50 were tap water samples, 40 from wells and 6 each were from Rawal and Simly dams. About 47% and 67% tap water samples, while 62% and 74% well water samples were found unsatisfactory from around Islamabad and Rawalpindi areas, respectively. About 83% and 66% water samples from Rawal dam and Simly dam respectively were found to be unsatisfactory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiometric method for the detection of coliform organisms in water.

A new radiometric method for the detection of coliform bacteria in water has been described. The method is based on the release of (14)CO(2) from [(14)C]lactose by bacteria suspended in growth medium and incubated at 37 C. The evolved (14)CO(2) is trapped by hyamine hydroxide and counted in a liquid scintillation spectrometer. The method permits the detection of 1 to 10 organisms within 6 h of ...

متن کامل

Comparison of nine brands of membrane filter and the most-probable-number methods for total coliform enumeration in sewage-contaminated drinking water.

Nine different brands of membrane filter were compared in the membrane filtration (MF) method, and those with the highest yields were compared against the most-probable-number (MPN) multiple-tube method for total coliform enumeration in simulated sewage-contaminated tap water. The water was chlorinated for 30 min to subject the organisms to stresses similar to those encountered during treatment...

متن کامل

A comparison of ten USEPA approved total coliform/E. coli tests.

Since 2002, the United States Environmental Protection Agency (USEPA) has approved ten enzyme-based total coliform and E. coli detection tests for examination of drinking water. These tests include: Colilert, Colilert-18, Colisure, m-Coli Blue 24, Readycult Coliforms 100, Chromocult, Coliscan, E * Colite, Colitag and MI Agar. The utility of the enzyme based test systems is based on both the abi...

متن کامل

Rapid Monitoring of Indicator Coliforms in Drinking Water by an Enzymatic Assay

Coliform group has been extensively used as an indicator of drinking water quality and historically led to the public health protection concept. Multiple tube fermentation technique has been currently used for assessment of the microbial quality of drinking water. This method, however, has limitations. Enzymatic assay constitute an alternative approach for detecting indicator bacteria, namely t...

متن کامل

Relationship between Turbidity and Residual Chlorine and Microbial Quality of Drinking Water

Abstract Background and Objective: Safe drinking water is essential for health and health promotion is dependent on providing safe water. We aimed to determine the relationship between turbidity & residual chlorine and microbial quality of drinking water in Agh ghala. Material and Methods: In this descriptive-analytical study, 2079 water samples were collected from water networks of 78 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JPMA. The Journal of the Pakistan Medical Association

دوره 41 7  شماره 

صفحات  -

تاریخ انتشار 1991