Immediate non-occlusal loading of immediate post-extractive versus delayed placement of single implants in preserved sockets of the anterior maxilla: 4-month post-loading results from a pragmatic multicentre randomised controlled trial.

نویسندگان

  • Pietro Felice
  • Elisa Soardi
  • Maurizio Piattelli
  • Roberto Pistilli
  • Michele Jacotti
  • Marco Esposito
چکیده

PURPOSE To compare the effectiveness of immediate post-extractive single implants with delayed implants placed in preserved sockets after 4 months of healing. Implants that achieved an insertion torque of at least 35 Ncm were immediately non-occlusally loaded. MATERIALS AND METHODS Just after tooth extraction and in the presence of a loss of the buccal plate bone less than 4 mm, compared to the palatal wall, 106 patients requiring a single immediate postextractive implant in the maxilla from second premolar to second premolar were randomly allocated to immediate implant placement (immediate group; 54 patients) or to socket preservation using anorganic bovine bone covered by a resorbable collagen barrier (delayed group; 52 patients) according to a parallel group design at three different centres. Bone-to-implant gaps were to be filled with anorganic bovine bone, however this was not done in 17 patients (corresponding to 40% of those who should have been grafted). Four months after socket preservation, delayed implants were placed. Implants placed with an insertion torque >35 Ncm were immediately loaded with non-occluding provisional single crowns, replaced, after 4 months, by definitive crowns. Outcome measures were implant failures, complications, aesthetics assessed using the pink esthetic score (PES), and patient satisfaction, recorded by blinded assessors. All patients were followed up to 4 months after loading. RESULTS Nineteen (35%) implants were not immediately loaded in the immediate group versus 39 (75%) implants in the delayed placement group because an insertion torque >35 Ncm could not be obtained. No patient dropped out. Two implants failed in the immediate group (4%) versus none in the delayed group. More minor complications occurred in the immediate group (8) than the in the delayed group (1) and this was statistically significant (P = 0.032). At delivery of definitive crowns, 4 months after loading, aesthetics were scored as 12.8 and 12.6 in the immediate and delayed groups, respectively. There was no statistically significant difference (P = 0.5). Patients of both groups were equally satisfied. CONCLUSIONS There were more complications at immediate post-extractive implants when compared to delayed implants. The aesthetic outcome appears to be similar for both groups and it seems more difficult to obtain a high insertion torque in sockets preserved with anorganic bovine bone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immediate loading in dental implants ( A literature review )

Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...

متن کامل

Guided bone regeneration with and without a bone substitute at single post-extractive implants: 1-year post-loading results from a pragmatic multicentre randomised controlled trial.

OBJECTIVES To evaluate whether the adjunctive use of a bone substitute at immediate single implants placed in fresh extraction sockets with a residual buccal bone-to-implant gap of at least 1 mm could improve the aesthetic outcome of guided bone regeneration (GBR). MATERIALS AND METHODS Eighty patients requiring bone augmentation at a single immediate postextractive implant to improve the aes...

متن کامل

Immediate non-occlusal loading of single implants in the aesthetic zone: a randomized clinical trial.

AIM this study compared the outcome of immediate non-occlusal loading with conventional loading for single implants in the maxillary aesthetic zone. It was hypothesized that immediate non-occlusal loading is not inferior to conventional loading. MATERIALS AND METHODS sixty-two patients with a missing maxillary anterior tooth were randomly assigned to be treated with an implant that was either...

متن کامل

Immediate, early (6 weeks) and delayed loading (3 months) of single implants: 4-month 
post-loading from a multicenter pragmatic randomised controlled trial.

PURPOSE To compare the clinical outcome of single, partial and full fixed implant-supported prostheses immediately loaded (within 48 h), early loaded at 6 weeks and conventionally loaded at 3 months (delayed loading). MATERIALS AND METHODS Eighty-one patients (27 requiring single implants, 27 requiring partial fixed prostheses and 27 requiring total fixed cross-arch prostheses) were randomise...

متن کامل

Success rate of immediate loading of single OPILS implants of Neo-Dent system

Success rate of immediate loading of single OPILS implants of Neo-Dent system Dr. SH. Namjoy Nik * - Dr. SH. Shahab ** - Dr. M. Mohammad Poor*** - Dr. A. Balooch*** *- Assistant Professor of Oral and Maxillofacial Surgery Dept. - Faculty of Dentistry – Shahed University. **- Assistant Professor of Oral Radiology Dept. Faculty of Dentistry – Shahed University. ***- Dentist. Background and Aim: I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of oral implantology

دوره 4 4  شماره 

صفحات  -

تاریخ انتشار 2011