Treatment of keratoconus with Ferrara ICRS and consideration of the efficacy of the Ferrara nomogram in a 5-year follow-up.
نویسندگان
چکیده
PURPOSE To investigate Ferrara intrastromal ring segments (FIRS) as a therapeutic opportunity to treat keratoconus (KC), to reduce the necessity for cornea transplant, and to improve quality of vision of patients with this disease. We demonstrate that the procedure is safe, reversible, and reliable, and can delay/stop the KC progression. METHODS A total of 130 eyes of 83 patients with KC, intolerant to contact lenses, implanted with FIRS were considered. Average follow-up was 37 months with a minimum of 2 years and a maximum of 5 years. For all patients, manifest refraction, uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA) corneal map, Orbscan, and intraoperative pachymetry were performed and were compared to postoperative measurements. RESULTS A total of 93.84% (122 patients) of the eyes gained lines of UCVA and only 1.53% (2 eyes) lost them. A total of 97.69% (127 patients) of the treated eyes gained lines of BCVA and no eyes lost them. The value of K1 and K2 were considerably reduced over 5 years. The preoperative value of K average of 49.27 D became 4.68 D postoperatively. Both the UCVA and the BCVA showed an increase. The UCVA changed from 0.14 lines preoperatively to 0.32 postoperatively while the BCVA changed from 0.40 to 0.59. The spherical equivalent changed from -8.34 D before the operation to -2.83 D after the operation. CONCLUSIONS FIRS make KC cornea more regular and the patients have increased corrected and uncorrected visual acuity postoperatively. The progression of KC was stopped and the cornea thickness minimally, but regularly, improved.
منابع مشابه
Refractive and topographic results after exchange of Intacs SK for Ferrara intrastromal corneal ring segments after unsuccessful implantation for keratoconus correction
In the past, the main goal of intrastromal corneal ring segment (ICRS) implantation was to reduce keratometry. Current treatment nomograms based on classifi cation of the ectasia phenotype aim to provide both therapeutic and refractive correction. We present the case of a 39-year-old woman diagnosed in 2011 with keratoconus in both eyes, with low best spectacle-corrected distance visual acuity ...
متن کاملLong-term follow-up of intrastromal corneal ring segments in keratoconus.
PURPOSE To report the long-term follow-up of Ferrara intrastromal corneal ring segment (ICRS) implantation for the management of keratoconus. SETTING Private clinic, Belo Horizonte, Brazil. METHODS This study comprised patients with keratoconus who completed at least 5 years of follow-up. One or 2 ICRS were inserted in the cornea, embracing the keratoconus area. Statistical analysis include...
متن کاملClinical outcomes after intrastromal corneal ring segments reoperation in keratoconus patients.
AIM To evaluate the clinical outcomes after Ferrara intrastromal corneal ring segments (ICRS) reoperation in patients with keratoconus. METHODS A total of 37 keratoconus eyes implanted with intrastromal corneal ring segments, which had an ICRS exchange, addition, reposition or removal were evaluated. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), keratometry (K), asphe...
متن کاملLong-term Follow-up of Ferrara Rings Segments for the Treatment of Keratoconus
Purpose: To evaluate the long-term results of Ferrara rings intracorneal ring segments for the treatment of keratoconus. Setting: Private medical center, Ophthalmology Department, Hadassah Optimal Medical Center, Haifa, Israel. The National Center for the Treatment of Keratoconus Haifa, Israel. Materials and methods: Retrospective review of data for patients implanted with Ferrara intrastromal ...
متن کاملLong-Term Follow-Up of Intrastromal Corneal Ring Segments in Paracentral Keratoconus with Coincident Corneal Keratometric, Comatic, and Refractive Axes: Stability of the Procedure
PURPOSE To assess the long-term outcomes of implanting intrastromal corneal ring segments (ICRS) in paracentral keratoconic eyes. METHODS 58 eyes with paracentral keratoconus with coincident refractive, keratometric, and comatic axes were evaluated. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity and refractive errors were recorded before and at all follow-up visits. The postop...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of ophthalmology
دوره 20 5 شماره
صفحات -
تاریخ انتشار 2010