Doubly Fed Induction Generator and Conventional Synchronous Generator Based Power Plants: Operation during Grid Fault

نویسندگان

  • M. B. C. Salles
  • A. P. Grilo
  • J. R. Cardoso
چکیده

The use of doubly fed induction generator in wind power plants has result in new necessities to maintain a reliable operation of the network. The tendency of the grid codes is to require the ability from the wind power plant to keep connected during and after grid disturbance, similarly to the synchronous generators requirements. This paper analyse the behaviour of a wind power plant equipped with doubly fed induction generators connected to a transmission system during grid fault and compare its performance with a conventional synchronous generator based power plant. The results have shown that the conventional synchronous generator has much more effective injection of reactive power during grid fault and, by consequence, the terminal voltage is kept in higher levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sliding-Mode-based Improved Direct Active and Reactive Power Control of Doubly Fed Induction Generator under Unbalanced Grid Voltage Condition

This paper proposes an improved direct active and reactive power control (DPC) strategy for a grid-connected doubly fed induction generator (DFIG) based wind-turbine system under unbalanced grid voltage condition. The method produces required rotor voltage references based on the sliding mode control (SMC) approach in stationary reference frame, without the requirement of synchronous coordinate...

متن کامل

Loss of Excitation Detection in Doubly Fed Induction Generator by Voltage and Reactive Power Rate

The doubly fed induction generator (DFIG) is one of the most popular technologies used in wind power systems. With the growing use of DFIGs and increasing power system dependence on them in recent years, protecting of these generators against internal faults is more considered. Loss of excitation (LOE) event is among the most frequent failures in electric generators. However, LOE detection stud...

متن کامل

Optimal Operation of Doubly-fed Induction Generator used in a Grid-Connected Wind Power System

In this paper, a wind power system based on a doubly-fed induction generator (DFIG) is modeled and simulated. To guarantee high-performance control of the powers injected into the grid by the wind turbine, five intelligent super-twisting sliding mode controllers (STSMC) are used to eliminate the active power and current ripples of the DFIG. The STSMC controller is a high-order sliding mode cont...

متن کامل

Low Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage

In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...

متن کامل

Novel design and simulation of predictive power controller for a doubly-fed induction generator using rotor current in a micro-hydropower plant

Hydropower plant and especially micro-hydropower plant is an available, reliable and economical energy source. Micro-hydropower plant is one of the most environment-friendly technology, use and development of which leads to reduction of energy consumption sporadically and worldwide. Along with the growth of these power plants, the issues related to the control of electrical parameters such ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011