Acoustic Analysis of Used Tuning Forks.
نویسندگان
چکیده
OBJECTIVE In this study, we evaluated used aluminum tuning forks (TFs) for fundamental frequencies (FF), overtones, and decay times. MATERIALS AND METHODS In total, 15 used (1 C1, 11 C2, and 3 C3) and 1 unused (C2) TFs were tuned, and the recorded sound data were analyzed using the Praat sound analysis program. RESULTS It was found that FFs of the recorded sounds produced by the used C2-TFs presented a high variability from 0.19% to 74.15% from the assumed FFs, whereas this rate was smaller (1.49%) in the used C3-TFs. Further, decay times of the used C2-TFs varied from 5.41 to 40.97 s. CONCLUSION This study, as the first of its kind in the literature, reported that some of the used aluminum TFs lost their physical properties that are important for clinical TF tests. It could be said that this is a phenomenon related to metal fatigue, which is common in aluminum products due to the cyclic load.
منابع مشابه
The Prague historical collection of tuning forks: a surviving replica of the Koenig tonometre
Despite the copious advances in acoustic techniques and devices for measuring and displaying acoustic parameters, a steady component of a phonetician’s scientific method remains to be – to this very day – our hearing. This paper therefore focuses on a historical device shared between acoustics and auditory phonetic analysis: Rudolph Koenig’s Grand Tonometre, consisting of more than a hundred tu...
متن کاملRinne revisited: steel versus aluminum tuning forks.
OBJECTIVE (1) Determine whether tuning fork material (aluminum vs stainless steel) affects Rinne testing in the clinical assessment of conductive hearing loss (CHL). (2) Determine the relative acoustic and mechanical outputs of 512-Hz tuning forks made of aluminum and stainless steel. STUDY DESIGN Prospective, observational. SETTING Outpatient otology clinic. SUBJECTS AND METHODS Fifty su...
متن کاملQuartz Enhanced Photoacoustic Spectroscopy Based Trace Gas Sensors Using Different Quartz Tuning Forks
A sensitive trace gas sensor platform based on quartz-enhanced photoacoustic spectroscopy (QEPAS) is reported. A 1.395 μm continuous wave (CW), distributed feedback pigtailed diode laser was used as the excitation source and H2O was selected as the target analyte. Two kinds of quartz tuning forks (QTFs) with a resonant frequency (f0) of 30.72 kHz and 38 kHz were employed for the first time as a...
متن کاملSimultaneous Detection of Static and Dynamic Signals by a Flexible Sensor Based on 3D Graphene
A flexible acoustic pressure sensor was developed based on the change in electrical resistance of three-dimensional (3D) graphene change under the acoustic waves action. The sensor was constructed by 3D graphene foam (GF) wrapped in flexible polydimethylsiloxane (PDMS). Tuning forks and human physiological tests indicated that the acoustic pressure sensor can sensitively detect the deformation ...
متن کاملReliability of Semmes-Weinstein Monofilaments and Tuning Fork on Pressure and Vibration Sensation Measurements in Diabetic Patients
Objectives: Sensory neuropathy is the major cause of ulceration in diabetic patients. Periodical sensory examination is an appropriate method to detect neuropathy and decrease the risk of diabetic foot ulcer. Semmes–Weinstein Monofilaments (SWM) and tuning fork on/off test are widely used to assess pressure and vibration sensitivity. The present study evaluated the inter- and intra-rater reliab...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of international advanced otology
دوره 13 2 شماره
صفحات -
تاریخ انتشار 2017