OBJECTIVE Current determinations of diagnostic ultrasound exposure parameters (eg, peak rarefactional pressure and pulse intensity integral) are intended to correspond to propagation through soft tissue with a propagation speed of 1540 m/s and attenuation of 0.3 dB x cm(-1) x MHz(-1). These current measurements are made in water, which has very little attenuation, and a linear derating factor is applied to approximate 0.3 dB x cm(-1) x MHz(-1) attenuation. The fact that propagation through water as well as through soft tissue involves nonlinear propagation is not directly addressed. A better way to determine exposure parameters would be to use a liquid that has the desired tissue-mimicking properties, including a value of the nonlinearity parameter B/A representative of soft tissue. To be of practical use in the laboratory, the ultrasonic properties of this liquid must remain stable and spatially uniform for many months or years without need for periodic mixing by the user. METHODS Fifty-two samples of fat-free milk that was concentrated to one third of its original volume by ultrafiltration were created. Each sample was preserved by a different method. The speed of sound, attenuation, and nonlinearity parameter B/A of each sample were periodically monitored by narrowband through-transmission techniques. RESULTS Six of the 52 samples remained liquid and retained acceptably stable acoustic properties over 22 months of storage at room temperature. CONCLUSIONS Fat-free milk, concentrated via ultrafiltration and preserved in 1 of 6 different methods, has been found to be a stable tissue-mimicking liquid with acoustic properties appropriate for use in exposimetry.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An exposimetry system using tissue-mimicking liquid.

Acoustic output measurements of diagnostic ultrasound scanners are currently performed in water and derated to approximate in situ values. The derating scheme ignores nonlinear propagation of sound waves and has been shown in previous numerical and experimental studies to tend to underestimate relevant pressure and intensity values in tissue mimicking media. This work describes an alternative m...

متن کامل

Dosimetry of 188Re and 186Re sources based on Monte Carlo calculations for endovascular brachytherapy after balloon angioplasty

Background: Recent pre-clinical and clinical studies indicate that irradiation in the dose range of 15 to 30 Gy can reduce rate of restenosis in patients who have undergone an angioplasty. The use of filled balloon with radioactive solution was proposed as one of the possible intravascular irradiation techniques. Materials and Methods: The Monte Carlo N-particle Transport Code (MCNP4b) was used...

متن کامل

Spinal Intradural Extramedulary Capillary Hemangioma Mimicking Meningioma

Hemangiomas are considered as vascular malformations which are categorized by the type of vascular channel to capillary, cavernous, venous or arteriovenous(1). Their usual locations are soft tissue , cutaneous or subcutaneous tissue and bone especially vertebra(2).However, intradural extramedullary hemangiomas are rare and most of them fall in cavernous type category. Hereby, authors report a w...

متن کامل

Acoustic measurements in a tissue mimicking liquid.

A liquid has been developed that mimics soft tissue in terms of propagation speed, attenuation, and nonlinearity parameter B/A. Since the slope of the attenuation coefficient is nearly constant up to at least 18 MHz and the value can be anywhere in the range 0.1 through 0.7 dB/(cm MHz), the material is ideal for assessing the effectiveness of attenuation derating of output acoustic intensities ...

متن کامل

In situ human obstetrical ultrasound exposimetry: estimates of derating factors for each of three different tissue models.

A specialized in vivo exposimetry system was developed to acquire transabdominal in situ ultrasound exposure quantities in obstetric patients. Under surgical conditions, the sterilized 7-element calibrated linear array hydrophone was introduced into the uterus under direct ultrasound guidance and placed in direct contact with the products of conception, usually in the saggital midplane of the u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine

دوره 24 4  شماره 

صفحات  -

تاریخ انتشار 2005