Objective selection of short-axis slices for automated quantification of left ventricular size and function by cardiovascular magnetic resonance

نویسندگان

  • Marco Marino
  • Victor Mor-Avi
  • Francesco Maffessanti
  • Cristiana Corsi
  • Amit R Patel
چکیده

BACKGROUND Quantification of left ventricular (LV) volume from cardiovascular magnetic resonance images relies on subjective and often challenging selection of short-axis (SAX) slices. We hypothesized that this could be solved by defining mitral annular (MA) plane and apex in long-axis (LAX) views, which could be combined with automated LV volume analysis that does not rely on manual tracing of the endocardial border. METHODS SAX images from 50 subjects were analyzed using custom software. LV apex and insertion points of the mitral leaflets were marked on LAX views and used to approximate MA plane. End-systolic and end-diastolic LV volumes (ESV, EDV) were measured while including only slices or their parts located between MA plane and LV apex. Endocardial borders were automatically detected using our previously validated algorithm and also manually traced to obtain reference values. RESULTS Selection of anatomic landmarks in LAX views allowed automated measurement of LV volumes without the need for subjective slice selection. Intertechnique comparisons resulted in high correlations (EDV: r=0.95; ESV: r=0.96) and small biases (1 and 9ml). Combined three-dimensional displays of LAX and SAX views with the MA plane showed that in 7/10 worst cases, intertechnique discordance was due to incorrect manual tracing at LV base that erroneously included part of atrial cavity in LV volume or excluded part of LV cavity, i.e., incorrect reference values. CONCLUSION Defining the MA plane and apex in the LAX views obviates the need for subjective slice selection and eliminates errors in LV volume measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reproducibility of short axis slice locations in longitudinal cardiovascular magnetic resonance (CMR) studies

Background Longitudinal dynamic changes of myocardial ischemic injury determine left ventricular (LV) remodelling. Using conventional clinical cardiovascular magnetic resonance (CMR) imaging, the registration of short axis (SA) images for comparison of imaging findings at different time points is aided by the application of the same protocol to consistently identify the atrio-ventricular (AV) g...

متن کامل

Comparison of long and short axis quantification of left ventricular volume parameters by cardiovascular magnetic resonance, with ex-vivo validation

BACKGROUND The purpose of the study was to compare the accuracy and evaluation time of quantifying left ventricular (LV), left atrial (LA) volume and LV mass using short axis (SAX) and long axis (LAX) methods when using cardiovascular magnetic resonance (CMR). MATERIALS AND METHODS We studied 12 explanted canine hearts and 46 patients referred for CMR (29 male, age 47 ± 18 years) in a clinica...

متن کامل

The Correlation between Left and Right Ventricular Ejection Fractions in Patients with Ischemic Heart Disease, Documented by Cardiac Magnetic Resonance Imaging

Introduction: The correlation between right and left ventricular ejection fractions (RVEF and LVEF, respectively) has been studied in only a small number of patients with a marked decrease in RVEF and LVEF. The aim of the present study was to compare LVEF and RVEF in patients with ischemic heart disease. RVEF and LVEF were measured by Cardiovascular Magnetic Resonance (CMR) imaging. Materials a...

متن کامل

Evaluation of a new method for automated detection of left ventricular boundaries in time series of magnetic resonance images using an Active Appearance Motion Model.

The purpose of this study was the evaluation of a computer algorithm for the automated detection of endocardial and epicardial boundaries of the left ventricle in time series of short-axis magnetic resonance images based on an Active Appearance Motion Model (AAMM). In 20 short-axis MR examinations, manual contours were defined in multiple temporal frames (from end-diastole to end-systole) in mu...

متن کامل

Accelerating global left-ventricular function assessment in mice using reduced slice acquisition and three-dimensional guide-point modelling

BACKGROUND To investigate the utility of three-dimensional guide-point modeling (GPM) to reduce the time required for CMR evaluation of global cardiac function in mice, by reducing the number of image slices required for accurate quantification of left-ventricular (LV) mass and volumes. METHODS Five female C57Bl/6 mice 8 weeks post myocardial infarction induced by permanent occlusion of the l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2015