Assumption constraints of fluorophotometry in human eyes.
نویسندگان
چکیده
We read with great interest the article entitled “Fluorophotometric Study of the Effect of the Glaukos Trabecular Microbypass Stent on Aqueous Humor Dynamics” by Fernández-Barrientos et al. The authors examined aqueous humor dynamics before and after surgery in eyes undergoing cataract surgery and the implantation of the bypass stent (group 1) and in eyes undergoing cataract surgery alone (group 2). They reported a significant increase in outflow facility in both groups, with the combined procedure group having the highest values. Outflow facility was calculated with aqueous flow assessed by fluorophotometry, a standard value of 10 mm Hg for episcleral venous pressure, and negligible uveoscleral outflow in the Goldmann equation. Fluorophotometry is a useful technique for assessment of aqueous humor dynamics, but it does have several assumptions that must be met for the technique to be valid. The anterior chamber fluorescein disappearance technique of Jones and Maurice requires the presence of an intact iridolenticular diaphragm, which is compromised in eyes undergoing cataract surgery with a lens implant. Most investigators familiar with the technique exclude from study any subject with prior ocular surgeries. In pseudophakic eyes, one can no longer assume that there is minimal loss of fluorescein into the vitreous cavity. Such a loss would manifest itself on fluorophotometry as an apparent increase in aqueous inflow. This can be seen from the results of Fernández-Barrientos et al. where aqueous flow values as high as 4.05 1.8 L/min (compared to a baseline of 1.78 0.44 L/min) were reported in group 1 at 6 months after the surgical procedure. The apparent increase in aqueous flow was found to be statistically significant in both groups at all but one measurement time in the postoperative period. There is no reason to believe that cataract surgery or the bypass stent itself would increase aqueous flow several months after the procedure is performed. Hence, it is likely that the higher values of aqueous flow obtained by the authors after surgery are the result of a systematic error introduced by the pseudophakic state of the eyes undergoing the measurement. This apparent increase in aqueous flow does seem to resolve spontaneously with time, as seen in their Table 4. At 1 year after surgery, the apparent increase in aqueous flow in group 2 was reduced to a level that differed by a statistically insignificant amount from baseline. Hence, it may be possible to obtain valid aqueous flow measurements in pseudophakic eyes with intact capsules a year or more after the cataract surgery. Fernández-Barrientos et al. also made the assumption that the pressure-independent outflow (uveoscleral outflow) is a negligible component in aqueous humor dynamics. More recent work has shown uveoscleral outflow to be a more significant contributor than the 10% cited in 1971 by Bill and Phillips. Since the purpose of Fernández-Barrientos et al. was to evaluate the effects on pressure-dependent outflow alone, it can be argued that uveoscleral outflow, even though a significant contributor to aqueous outflow, could have been ignored, because it was not expected to change with time and with any of the procedures performed in the study. However, this assumption may not be valid, as any surgical procedure on the anterior chamber angle has a very high probability of disturbing the supraciliary space and altering uveoscleral outflow. Making multiple attempts at proper device placement or implanting multiple devices would make inadvertent communication with the supraciliary space even more likely. An increase in uveoscleral outflow would be expected to lower the intraocular pressure (IOP). However, if the uveoscleral outflow is assumed to be negligible and unchanged, this decrease in IOP could be erroneously attributed to an improvement in the outflow facility. Further, the artifact in aqueous inflow measurements introduces a systematic error in the calculation of outflow facility that makes the improvement in outflow facility look better than it may have been. As can be seen from the formula used to calculate the outflow facility, [CT F/(IOP Pev)], any errors in measurement of aqueous flow (F) would directly influence the calculated outflow facility (CT). We feel that the only valid aqueous flow measurement that satisfies the prerequisite of a fluorophotometric assessment is the one obtained before surgery. Since cataract surgery with or without the microbypass stent should not be expected to change the aqueous humor production rate at the time of the measurement, these values may be used for the calculation of outflow facility after the procedure. The effects of an erroneous F in the outflow facility calculation can be seen in Table 1. The IOP data (after washout of ocular medications) at the time of fluorophotometry is not provided in the article; however, the mean IOP gradient can be calculated readily by using the reported means of F and CT as IOP gradient F/CT. As can be seen from the table, at 1 year, the mean CT of 0.27 L/min/mm Hg in group 1 versus 0.16 L/min/mm Hg in group 2 is more likely to be representative of outflow facility at these times. These values also are more consistent with the values obtained by Bahler et al., who reported an 84% increase in outflow facility after placement of the bypass stent in cultured human anterior segments.
منابع مشابه
Corneal permeability changes in dry eye disease: an observational study
BACKGROUND Diagnostic tests for dry eye disease (DED), including ocular surface disease index (OSDI), tear breakup time (TBUT), corneal fluorescein staining, and lissamine staining, have great deal of variability. We investigated whether fluorophotometry correlated with previously established DED diagnostic tests and whether it could serve as a novel objective metric to evaluate DED. METHODS ...
متن کاملEffect of thymoxamine on aqueous humor formation in the normal human eye as measured by fluorophotometry.
A double-blind, randomized, placebo-controlled study of the effect of 0.5% topical thymoxamine hydrochloride an alpha-adrenergic antagonist, on the rate of aqueous humor formation in the eyes of 25 normal human subjects was performed with fluorophotometry. The effect of thymoxamine on intraocular pressure and anterior chamber volume was also studied. four of the 25 subjects were used to study t...
متن کاملBioavailability of fluorescein from a new drug delivery system in human eyes.
AIM To assess the ocular bioavailability of fluorescein from a novel drug delivery system compared with one single preservative free eye drop. METHODS Part A: In a randomised study 10 volunteers applied the lyophilisate to one eye and a conventional fluorescein eye drop to the fellow eye. Fluorophotometry was performed before and every 2 minutes up to 30 minutes after application in the corne...
متن کاملMethod of measuring aqueous humor flow and corneal endothelial permeability using a fluorophotometry nomogram.
A new method of measuring aqueous humor flow and corneal endothelial permeability to fluorescein using a fluorophotometry nomogram is described. This method is compared to four other methods, two of which have been described previously. All five methods were carried out simultaneously in a group of 20 normal human subjects. All methods give closely comparable results in most of the eyes tested....
متن کاملSCIENTIFIC REPORT Bioavailability of fluorescein from a new drug delivery system in human eyes
Aim: To assess the ocular bioavailability of fluorescein from a novel drug delivery system compared with one single preservative free eye drop. Methods: Part A: In a randomised study 10 volunteers applied the lyophilisate to one eye and a conventional fluorescein eye drop to the fellow eye. Fluorophotometry was performed before and every 2 minutes up to 30 minutes after application in the corne...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 52 3 شماره
صفحات -
تاریخ انتشار 2011